Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1593020.1
Update Date:2018-05-25
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1593020.1 :   Sun ZFS Storage Appliance: SAS-8000-5Y - SAS HBA to storage enclosure not properly configured  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS5-2
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Oracle ZFS Storage ZS5-4
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun ZFS Storage 7120
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Purpose
Details
References


Applies to:

Oracle ZFS Storage ZS3-4 - Version All Versions and later
Oracle ZFS Storage ZS3-2 - Version All Versions and later
Sun ZFS Storage 7420 - Version All Versions and later
Sun ZFS Storage 7320 - Version All Versions and later
Sun ZFS Storage 7120 - Version All Versions and later
7000 Appliance OS (Fishworks)

Purpose

Provide additional information for message ID: SAS-8000-5Y

Details

Type: Fault

    fault.io.sas.hba.same-enc

 

Severity: Major

Description

The SAS cable path to a chain of storage enclosures is connected the same controller HBA creating a single point of failure.

Automated Response

None

 

Impact

Degradation in service due to specific subsystems/resources removed from operation.

 

Suggested Action for System Administrator

Prior to submitting a service request the storage/system administrator should perform the following SAS cable check:

  • Utilize the ZFS Maintenance BUI to identify the faulty SAS interface.
  • Review cabling diagrams in the online help or refer to the Quick Setup poster that shipped with the product. Also available is the Oracle ZFS Storage Appliance Installation Guide, located on the Oracle Technical Network documentation site.
  • Correct the cabling problem.
  • Verify via the Maintenance BUI the active fault has cleared 

  • If the fault has cleared returned the ZFS appliance to normal operation

  • If the fault persists, refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required

PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)

 

 

 

***Checked for relevance on 25-MAY-2018***

References

<NOTE:1432269.2> - Information Center: Sun ZFS Storage Appliances
<NOTE:1019887.1> - Sun Storage 7000 Unified Storage System: How to Collect a Support Bundle using the BUI or CLI
<NOTE:1416406.1> - Sun ZFS Storage Appliances Troubleshooting Resource Center

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback