![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1591871.1 : ILOM-8000-56 - Unexpected Error Telemetry
In this Document
Applies to:SPARC M7-16SPARC M7-4 SPARC T7-2 SPARC T7-4 SPARC M7-8 Information in this document applies to any platform. PurposeProvide additional information on MSG-ID ILOM-8000-56 DetailsType: Fault defect.ilom.fdd.unexpected_telemetry fault.ilom.fdd.unexpected_telemetry Severity: Major Description: The fault diagnosis daemon (fdd) that is a component of the ILOM software running on the service processor has received unexpected error telemetry and is therefore unable to provide a diagnosis describing the suspect hardware fault or software/firmware defect. This typically indicates a problem within the ILOM software. However, the error telemetry may indicate the presence of an actual hardware fault. Automated Response: The error events describing the unexpected error telemetry have been logged to support the diagnosis and resolution of this problem. Impact: Automated diagnosis and fault handling response for these events will not occur. The impact on system operation will vary depending on the actual effects of the reported error events. Suggested Action for System Administrators: Submit a Service Request to have this problem diagnosed and resolved by Oracle Support Services. Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required. PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1) Attachments This solution has no attachment |
||||||||||||||||
|