Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1588654.1
Update Date:2017-06-07
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1588654.1 :   SL150 - 9080 Magazine Open or Unlatched  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Purpose
Details
 Type:
 Severity:
 Description
 Automated Response
 Impact
 Suggested Action for System Administrators


Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Purpose

To provide additional information for message ID: 9080.mag.open.or.unlatched

Details

9080.mag.open.or.unlatched

Type:

SDP2

Severity:

Moderate

Description

MAG_OPEN_OR_UNLATCHED

Magazine open or unlatched

Automated Response

none

Impact

The robot will not operate when a magazine is open or unlatched.

Suggested Action for System Administrators

Close magazine. Re-seat/replace controller. Inspect/replace module chassis - the magazine open closed sensor is attached to the chassis.

Diagnostics should be gathered including logs and core files of the failure, please reference Doc ID 1474118.1


Note: If ASR (Automatic Service Request) has been enabled for this system, a Service Request should already be initiated. If ASR is not enabled and have a valid service contract please contact Oracle Support to assist in enabling ASR.