Asset ID: |
1-79-1574320.1 |
Update Date: | 2017-08-01 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1574320.1
:
Solaris 11 Host Driver Limitation on Virtual Resources Supported per Server in OVN (Formerly Xsigo)
Related Items |
- Oracle Fabric Interconnect F1-15
- Oracle Fabric Interconnect F1-4
|
Related Categories |
- PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
|
In this Document
Applies to:
Oracle Fabric Interconnect F1-15 - Version All Versions and later
Oracle Fabric Interconnect F1-4 - Version All Versions and later
Information in this document applies to any platform.
Purpose
This document specifics how many vNIC's and vHBA's can be deployed per solaris server.
Scope
Virtual Resources Supported per Server
Details
Virtual Resources Supported per Server
On Solaris servers, 8 vNICs and 4 vHBAs per server have been tested in this release.
• vNICs support:
— a maximum of 8 standalone vNICs.
— HA vNICs are not yet supported from the Fabric Interconnect. However, server-based HA vNICs are available natively though the IPMP on the Solaris server.
• vHBAs support:
— a maximum of 4 standalone vHBAs.
— Connectivity to commonly available Brocade FC switches in fabric-port mode (f-port). NPIV login must be enabled on the FC switch.
— Dynamic LUN discovery is supported in situations when no LUN masking is present and either an RSCN message is sent from the storage target, or a user-initiated rescan occurs on the vHBA.
— HA vHBAs (multipathing) are not yet supported.
Attachments
This solution has no attachment