Solution Type  Predictive Self-Healing Sure

Solution  1571054.1 :   Performing an AC power cycle on the T3/T4/T5/S7/T7/T8 Servers  


Related Items
  • SPARC T4-2
  •  
  • SPARC T8-1
  •  
  • SPARC T4-4
  •  
  • SPARC T7-2
  •  
  • Netra SPARC S7-2
  •  
  • SPARC T5-4
  •  
  • SPARC T3-4
  •  
  • SPARC T8-4
  •  
  • SPARC T3-1
  •  
  • SPARC T5-2
  •  
  • SPARC T4-1
  •  
  • SPARC T3-2
  •  
  • SPARC T8-2
  •  
  • SPARC T7-4
  •  
  • SPARC S7-2L
  •  
  • SPARC T7-1
  •  
  • SPARC T5-8
  •  
  • SPARC S7-2
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T3
  •  




In this Document
Purpose
Details
References


Applies to:

SPARC T7-1 - Version All Versions to All Versions [Release All Releases]
SPARC T3-1 - Version Not Applicable to Not Applicable [Release N/A]
SPARC T7-4 - Version All Versions to All Versions [Release All Releases]
SPARC T4-4 - Version Not Applicable to Not Applicable [Release N/A]
SPARC T4-2 - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Purpose

 This document is written  to facilitate performing an AC power cycle on the T3/T4/T5/S7/T7/T8 Servers

Details

 There are circumstances where part of an action plan  to resolve a system issue may require an AC power cycle, also known as a complete power cycle. This differs from power cycle initiated through ILOM commands such as "stop /SYS" as 3.3v standby power is always present in the system . You must unplug the AC power cords to perform a complete power cycle. It is recommended that  all the AC cords are removed from where they connect to the system itself and remain all unplugged for 75 seconds or greater

 

There is an additional step required for T7-1, T7-2, T7-4, S7-2, S7-2L, T8-1, T8-2, and T8-4 Systems:

For all scenarios where an AC power cycle, or AC power down is required for a T7-x, S7-x and T8-x server please use the following steps prior to following the process above to pull the AC power cords

1) Enter the ILOM restricted shell.

Details about the ILOM Restricted can be found in document How to use Restricted Shell on ILOM 3.0.10 and later platforms (Doc ID 1302296.1)

Any user with the [a]dmin or the [s]ervice role can enter the Restricted Shell via the spsh shell.
No password is required to enter the Restricted Shell.

-> set SESSION mode=restricted

WARNING: The "Restricted Shell" account is provided solely
to allow Services to perform diagnostic tasks.

[(restricted_shell) T7-2-sp:~]#     <------  restricted shell prompt

 

2) Issue the "ac_off_sp" command

[(restricted_shell) T7-2-sp:~]# ac_off_sp

 

3) Follow process to remove AC power cords and wait 60 seconds before plugging them back in

 


 

 