![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1569250.1 : SPARC T3/T4 : MegaCLI exit codes and what they mean
The error code In this Document
Applies to:SPARC T3-1 - Version All Versions to All Versions [Release All Releases]SPARC T3-2 - Version All Versions to All Versions [Release All Releases] Netra SPARC T4-1 Server - Version All Versions to All Versions [Release All Releases] SPARC T4-1 - Version All Versions to All Versions [Release All Releases] SPARC T4-2 - Version All Versions to All Versions [Release All Releases] Oracle Solaris on SPARC (64-bit) PurposeWhen the MegaCLI command is executed it returns an exit code, this document is meant to explain what the exit code means ScopeThis document applies to SPARC T3/T4 servers shipped with the optional Sun Storage SAS PCIe RAID HBA INTERNAL (SG-SAS6-R-INT-Z ) DetailsWhen the MegaCLI command is executed, it always ends with an exit code. The value of the exit code may be used to determine the result of the current (MegaCli) request.
For Example root@netra-t4-1-sin06-a:/export/home/jack# ./MegaCli -v MegaCLI SAS RAID Management Tool Ver 8.02.07 Mar 16, 2011 (c)Copyright 2010, LSI Corporation, All Rights Reserved. Exit Code: 0x00 <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< HERE
MegaCLI Exit Codes
0x00 Command completed successfully 0x01 Invalid command 0x02 DCMD opcode is invalid 0x03 Input parameters are invalid 0x04 Invalid sequence number 0x05 Abort isn't possible for the requested command 0x06 Application 'host' code not found 0x07 Application already in use - try later 0x08 Application not initialized 0x09 Given array index is invalid 0x0a Unable to add missing drive to array, as row has no empty slots 0x0b Some of the CFG resources conflict with each other or the current config 0x0c Invalid device ID / select-timeout 0x0d Drive is too small for requested operation 0x0e Flash memory allocation failed 0x0f Flash download already in progress 0x10 Flash operation failed 0x11 Flash image was bad 0x12 Downloaded flash image is incomplete 0x13 Flash OPEN was not done 0x14 Flash sequence is not active 0x15 Flush command failed 0x16 Specified application doesn't have host-resident code 0x17 LD operation not possibe - CC is in progress 0x18 LD initialization in progress 0x19 LBA is out of range 0x1a Maximum LDs are already configured 0x1b LD is not OPTIMAL 0x1c LD Rebuild is in progress 0x1d LD is undergoing reconstruction 0x1e LD RAID level is wrong for requested operation 0x1f Too many spares assigned 0x20 Scratch memory not available - try command again later 0x21 Error writing MFC data to SEEPROM 0x22 Required HW is missing (i.e. Alarm or BBU) 0x23 Item not found 0x24 LD drives are not within an enclosure 0x25 PD CLEAR operation is in progress 0x26 Unable to use SATA(SAS) drive to replace SAS(SATA) 0x27 Patrol Read is disabled 0x28 Given row index is invalid 0x2d SCSI command done, but non-GOOD status was received - see mf.hdr.extStatus for SCSI_STATUS 0x2e IO request for MFI_CMD_OP_PD_SCSI failed - see extStatus for DM error 0x2f Matches SCSI RESERVATION_CONFLICT 0x30 One or more of the flush operations failed 0x31 FW real-time currently not set 0x32 Command issues while FW in wrong state (i.e. GET RECON when op not active) 0x33 LD is not OFFLINE - IO not possible 0x34 Peer controller rejected request (possibly due to resource conflict) 0x35 Unable to inform peer of communication changes (retry might be appropriate) 0x36 LD reservation already in progress 0x37 I2C errors were detected 0x38 PCI errors occurred during XOR/DMA operation 0x39 Diagnostics failed - see event log for details 0x3a Unable to process command as boot messages are pending 0x3b Returned in case if foreign configurations are imcomplete 0x3d Returned in case if a command is tried on unsupported hardware 0x3e CC scheduling is disabled 0x3f PD CopyBack operation is in progress 0x40 Selected more than one PD per array 0x41 Microcode update operation failed 0x42 Unable to process command as drive security feature is not enabled 0x43 Controller already has a lock key 0x44 Lock key cannot be backed-up 0x45 Lock key backup cannot be verified 0x46 Lock key from backup failed verification 0x47 Rekey operation not allowed, unless controller already has a lock key 0x48 Lock key is not valid, cannot authenticate 0x49 Lock key from escrow cannot be used 0x4a Lock key backup (pass-phrase) is required 0x4b Secure LD exist 0x4c LD secure operation is not allowed 0x4d Reprovisioning is not allowed 0x4e Drive security type (FDE or non-FDE) is not appropriate for requested operation 0x4f LD encryption type is not supported 0x50 Cannot mix FDE and non-FDE drives in same array 0x51 Cannot mix secure and unsecured LD in same array 0x52 Secret key not allowed 0x53 Physical device errors were detected 0x54 Controller has LD cache pinned 0x55 Requested operation is already in progress 0x56 Another power state set operation is in progress 0x57 Power state of device is not correct 0x58 No PD is available for patrol read 0x59 Controller resert is required 0x5a No EKM boot agent detected 0x5b No space on the snapshot repositiry VD 0x5c For consistency SET PiTs, some PiT creations might fail and some succeed 0xFF Invalid status - used for polling command completion Attachments This solution has no attachment |
||||||||||||||||
|