![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1560499.1 : X3-2B (formerly Sun Blade X6270M3 Server module) and Netra X3-2B (formerly Sun Netra X6270M3 Server module) blades exhibiting false FMA faults SPX86-8003-PD on both CPUs.
Applies to:Sun Blade X3-2B - Version Not Applicable and laterNetra Blade X3-2B - Version Not Applicable and later Sun Blade 6000 System - Version Not Applicable and later Sun Netra 6000 System - Version Not Applicable and later Sun Netra 6000 Modular System M2 - Version Not Applicable and later Information in this document applies to any platform. PurposeThis document contains the details of X3-2B (formerly Sun Blade X6270M3 Server module) and Netra X3-2B (formerly Sun Netra X6270M3 Server module) blades exhibiting false FMA faults SPX86-8003-PD on both CPUs. To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Sun x86 Systems
DetailsTitle: X3-2B (formerly Sun Blade X6270M3 Server module) and Netra X3-2B (formerly Sun Netra X6270M3 Server module) blades exhibiting false FMA faults SPX86-8003-PD on both CPUs.
The VPP is a "Virtual Pin Port" which connects between the SandyBridge IIO and the hotplug FPGA controller. This issue occurs very intermittently but when a VPP error occurs, all the hotplug or cold plug operations for EMs and NEMs will fail. Our product development team has stated these errors should be ignored. If you see these errors then clear the FMA faults in ILOM and continue operation.
Please clear the faults in ILOM using following procedure: To clear the faults do the below: 1. First start a fault management shell: -> start /SP/faultmgmt/shell 2. Then clear the fault on both CPUs: faultmgmtsp> fmadm acquit /SYS/MB/P0
faultmgmtsp> fmadm acquit /SYS/MB/P1 faultmgmtsp> exit The faults should be gone after this.
To permanently fix these errors from happening the firmware ILOM/BIOS needs to be upgraded to SW1.2 release Patch 16008446 for X3-2B (formerly Sun Blade X6270M3 Server module) and patch 16026069 for Netra X3-2B (formerly Sun Netra X6270M3 Server module). Attachments This solution has no attachment |
||||||||||||
|