Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1548025.1
Update Date:2016-02-15
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1548025.1 :   Sun 7000 Unified Storage System: Clustered heads may cause duplicate alarms  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage Appliance Racked System ZS4-4
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Purpose
Details
References


Applies to:

Sun Storage 7410 Unified Storage System - Version All Versions and later
Sun ZFS Storage 7420 - Version All Versions and later
Sun ZFS Storage 7320 - Version All Versions and later
Oracle ZFS Storage ZS3-2 - Version All Versions and later
Oracle ZFS Storage ZS3-4 - Version All Versions and later
7000 Appliance OS (Fishworks)

Purpose

The purpose of this document is to increase awareness of the possibility of duplicate alarms being raised on a clustered system.

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage ZFS Storage Appliance

Details

For all Appliance Firmware 2011.1.x Releases and 2013.1.2.13 (or earlier), you may see the same alarm on both heads (duplicate) for hardware resources that are shared between cluster peers.

This is a known issue and is fixed in Appliance Firmware Release 2013.1.3.0.

 

In the meantime, we are detecting these duplicate requests to prevent redundancy.

You may close this duplicate Service Request at your convenience or allow the system to close it automatically after 14 days.

 

Please see Doc ID 2021771.1 for the latest Appliance Firmware Release version.

 

 