Asset ID: |
1-79-1540688.1 |
Update Date: | 2018-02-16 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1540688.1
:
Oracle 10-Gigabit Ethernet Switches Support
Related Items |
- Oracle Ethernet Switch ES2-72
- Oracle Switch ES1-24
- Oracle Ethernet Switch ES2-64
- Sun Network Switch
- Sun Blade 6000 System
|
Related Categories |
- PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
- _Old GCS Categories>Sun Microsystems>Operating Systems>Solaris Network
|
In this Document
Applies to:
Oracle Switch ES1-24
Oracle Ethernet Switch ES2-64
Oracle Ethernet Switch ES2-72
Sun Network Switch
Sun Blade 6000 System
Information in this document applies to any platform.
Purpose
This document contains support information for the SUN 10-Gigabit Ethernet Switches:
Oracle Switch ES2-64/64p and ES2-72 Oracle Switch ES1-24 10GE Switch 24p Sun Blade 6000 Ethernet Switched NEM 24p 10GE Sun Network 10GE Switch 72p
Scope
Details
The Sun Blade 6000 Ethernet Switched Network Express Module (NEM) 24p 10GE (Opus C10 NEM) is a multipurpose connectivity module for the Sun Blade 6000 modular system. The Switched NEM supports connections to external devices through 10 Gigabit Ethernet (10GE) SFP+ ports and QSFP ports as well as connections to internal server modules (blades) in a Sun Blade 6000 modular system chassis with disk modules in the same chassis.
The Sun Network 10GE Switch 72p (Opus 2 ToR) is a "Top of the Rack" switch with 16 QSFP (64x 10GE) and 8 SFP+ (1/10 GE) ports.
The Oracle Switch ES1-24 (TOR) is a "Top of the Rack" switch with 20 copper (1/10 GE) ports. and 4 SFP+ (1/10 GE) ports and is mostly be deployed as an Access Layer switch.
The Oracle Switch ES2-64 is a "Top of the Rack" switch with 40 Copper (1/10 GE) and 6 QSFP (24x10GE) ports. The QSFP ports can be configures to support 40Gb Ethernet.
The Oracle Switch ES2-72 Is a "Top of the Rack" switch with 18 QSFP (72x10GE) ports
-
Sun Blade 6000 Ethernet Switched NEM 24p 10GE
- 10GE network switching between blades and external network up links
- 10 internal ports, 1 x 10GE per server blade
- 14 external ports via 3 QSFP and 2 SFP+ connectors
- FreeScale PPC8547E Ethernet fabric control processor
- SAS2 storage aggregation
- 20 internal ports, 2 per server blade
- Internal Chassis Management Module (CMM) connectivity
- External management ports
- 1 serial service port to PPC8547E control processor
-
Sun Network 10GE Switch 72p
- 1 RU 72 ports non-blocking 10GE switching; expressed as
- 16 fixed QSFP connectors (64 10GE ports) and
- 8 SFP+ connectors
- External management ports
- 1 serial port
- 2x 10/100/1000 Base-T RJ-45
- 1+1 redundant power supply
- 4+1 redundant fans
- Support reversible air flows
- Chassis supports mounting on either 'front' or 'back'
- DOES NOT Support LLA Feature which allows port channel on host to connect to two switches.
- 1 RU (half width) 24 ports non-blocking 10GE switching; expressed as
- 20 copper 10 Gb RJ45 connectors
- 4 10 Gb SFP+ connectors
- External management ports
- 1 serial port
- 2x 10/100/1000 Base-T RJ-45
- 1+1 redundant power supply
- 1+1 redundant fans
- Support reversible air flows
- Supports LLA Feature
- Oracle switch ES2-64
-
- 40 copper 10 Gb RJ45 connectors
- 6 QSFP 10 Gb connectors
- 1 serial port
- 1+1 redundant power supply
- 1+1 redundant fans
- Support reversible air flows
- Supports LLA Feature
-
Oracle switch ES2-72
-
- 18 QSFP 10Gb connectors
- 1 serial port
- 1+1 redundant power supply
- 1+1 redundant fans
- Support reversible air flows
Information Gathering
- Initial information needed for Service Request:
- Detailed problem description including error or warning messages.
- ILOM snapshot (please always get a "Full" ILOM snapshot to include event logs. There is no risk of a system reset on Opus despite the warning.
- ES1-24 - There is a script to collect all show outputs above. es1-24-bur09-b-sp SEFOS# run script getswitchinfo.sc <---Collect putty log. Do not redirect to flash.
- ES2 switches have a new command SEFOS#show tech-support. Collect this on all ES2 switches<---Collect putty log. Do not redirect to flash.
- 72P Tor FW 1.2.2.9 and above includes script getswitchinfo.sc SEFOS# run script getswitchinfo.sc <---Collect putty log. Do not redirect to flash.
- 72P Tor FW 1.2.2.15 and above includes show-techsupport SEFOS#show tech-support <---------------Collect putty log. Do not redirect to flash. Also collect getswitchinfo.sc
- NEM version 1.2.2.9 does not include gerswitchinfo.sc so manual data collection is required as described below.
- For manuel data collections, run and collect the following show outputs (same output as the getswitchinfo.sc script)
- show running-config
show nvram
show system information
show interface status
show ip interface
show mac-address-table
show vlan
show spanning-tree detail
show ip route summary
show vlan
show interfaces flowcontrol
show ether detail
show ip rip stat
show int stat
show vrrp det
clear int count (set all counters to 0)
wait 20 seconds
show int count<<<<look for excessive packet counter wrapping.. Indicates a loop
- If the configuration includes a Sun Blade 6000 Ethernet Switched NEM 24p 10GE
-
- *Explorer* output of affected blade(s)
- *Explorer* output of a Working blade (if exists)
- Which slot is used for the blade(s)?
- CMM ILOM snapshot
- SOS report output for Linux systems
Manuals
Sun Blade 6000 Ethernet Switched NEM 24p 10Gbe Documentation
Sun Network 10GbE Switch ES1-24 24p Documentation
Oracle Switch ES2-72 and Oracle Switch ES2-64 Documentation
Patches:
Patch 13255111: SUN NETWORK 10GBE SWITCH 72P 1.2
Patch 13255101: SUN BLADE 6000 10GBE SWITCHED NEM 1.2
Patch 17050841: ORACLE SWITCH ES1-24 1.3
Patch 21378426: ORACLE ETHERNET SWITCH ES2-72/ES2-64 2.0
For old firmware versions see Document: Location of old versions of Opus Firmware (Doc ID 1952789.1)
References
<NOTE:1400605.1> - TSC Network Product Home
<NOTE:1399483.1> - 10-Gigabit Ethernet Switches (Opus) Product Page
Attachments
This solution has no attachment