![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1540273.1 : Manuals for DIMM requirements on Sun Fire V880 - V890 are misleading
In this Document
Applies to:Sun Fire V880 Server - Version Not Applicable and laterSun Fire V880z Visualization Server - Version Not Applicable and later Sun Fire V890 Server - Version Not Applicable and later Information in this document applies to any platform. PurposeThis document will server to correct the statements made is several manuals that state the all 4 DIMMs in a bank must be identical Manufacturing Vendor and Capacity. DetailsSeveral documents state that all DIMMs in a bank of four must be the same capacity and Manufacturing Vendor. This statement is incorrect. It is required that they be the same capacity, but there is no requirement that the DIMMs must all come from the same Manufacturing Vendor.
This is a list of documents known to make this inaccurate statement: Sun Fire V890 Server Owner's Guide [817-3956-12 Oct-2005, Revision A] Chap-3, Page-52 Attachments This solution has no attachment |
||||||||||||||
|