Predictive Self-Healing Sure
Solution
1537082.1
:
Important step needed on all blades in SB6000 chassis after updating CMM firmware from version 2.x to version 3.x
Related Categories |
- PLA-Support>Sun Systems>SPARC>Usx/Blade/Netra>SN-SPARC: SB60xx
|
In this Document
Applies to:
Sun Blade 6000 System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Purpose
Make sure Customers, Field, and Support Engineers are aware of a step needed after updating the CMM firmware from version 2.x to version 3.x .
Details
When upgrading a CMM from version 2.x to 3.x you will need to reset (--> reset /SP) each blades service processor (SP) in the SB6000 chassis. Interfaces have changed between ILOM 2.x and ILOM 3.x and the SP's need to be reset in order to use the right interfaces.