Solution Type Predictive Self-Healing Sure Solution 1531140.1 : Pillar Axiom: MaxRep PCP_EVT_REPL_INSUFFICIENT_RETENTION_SPACE
In this Document
Applies to:Pillar Axiom Volume Replicator Appliance - Version Not Applicable and laterPillar Axiom Replication Engine (MaxRep) - Version 2.0 to 2.0 [Release 2.0] Information in this document applies to any platform. PurposeProvide steps for system administrators to resolve PCP_EVT_REPL_INSUFFICIENT_RETENTION_SPACE events. If you still have questions after reading this article, go to the My Oracle Support Community - Pillar Axiom Storage System
DetailsPurposeEvent PCP_EVT_REPL_INSUFFICIENT_RETENTION_SPACE is an indication that the MaxRep replication engine has reached its limit for the maximum amount of data that can be stored on the retention LUN on the target MaxRep engine for a particular protection plan. Replicated data gets stored in the retention LUN to allow for the MaxRep engine to rollback the target LUN to historic points in time if necessary. All of this historic data gets stored in the retention LUN of MaxRep engine at the target location of the replication pair. Depending upon the length of time the historic data is maintained, and the change rate of the source LUN in a replication pair, the amount of data stored on the retention LUN can be quite large. A MaxRep can reach its retention space limit for two reasons:
Troubleshooting Steps
If the fault is valid there are three options to resolve the issue:
Attachments This solution has no attachment |
||||||||||||||||||
|