Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1529096.1
Update Date:2017-10-05
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1529096.1 :   Definition of the Administrative and Operational States for Virtual Devices Connected to OVN Chassis  


Related Items
  • Oracle Fabric Interconnect F1-15
  •  
  • Oracle Fabric Interconnect F1-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
  •  




In this Document
Purpose
Scope
Details


Applies to:

Oracle Fabric Interconnect F1-15 - Version All Versions and later
Oracle Fabric Interconnect F1-4 - Version All Versions and later
Information in this document applies to any platform.

Purpose

What does the "state" of the Virtual Device mean?

Scope

 The output of the "show vnic" or "show vhba" command and Oracle Fabric Manager report state and if-state for virtual devices. What do those different states mean?

Details

A virtual device (I/O port and I/O module) has two different states; administrative and operational state. Administrative state is controlled by the administrator of the Oracle Fabric Interconnect chassis and can be set up or down by using the "set" command. Operational state is determined by the environment (cables, switches, etc.).

These two states are reported for each virtual device and are separated by a slash.

Under normal circumstances a virtual device will report an administrative state of "up" and an operational state of "up" (shown in Oracle Fabric Manager and the Oracle Fabric Interconnect chassis CLI output as "up/up").

If the virtual device state reports "down/up" (administrative state = down, operational state = up) then a Oracle Fabric Interconnect administrator has issued a command to bring down a virtual interface. Likewise a command can be issued to bring the interface back up.

If the virtual device state reports "up/down" then something in the environment is preventing this interface from functioning properly. First check the physical port and module that are associated with the virtual device. If the physical port is "down" then the virtual device will not function. A physical port may be down because is has been set down by a Oracle Fabric Interconnect administrator or it may be a problem with the cables or switch connected to that physical port.

Some commands used to report interface state are:

show vnic
show vhba
show ioport
show iocard

 