Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1528906.1
Update Date:2017-08-14
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1528906.1 :   VLAN Tagging - Port and vNIC Modes  


Related Items
  • Oracle Fabric Interconnect F1-15
  •  
  • Oracle Fabric Interconnect F1-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
  •  




In this Document
Purpose
Details


Applies to:

Oracle Fabric Interconnect F1-15 - Version All Versions and later
Oracle Fabric Interconnect F1-4 - Version All Versions and later
Information in this document applies to any platform.

Purpose

 VLAN Tagging - Port and vNIC Modes

Details

 The Fabric Director does not check the validity of VLAN tagging modes. For example, the Fabric Director allows the following configuration:

 
  •  An Ethernet port or Link Aggregation Group (LAG) set to trunk mode and a vNIC terminating on that Ethernet port or LAG set to access mode. This configuration is valid and the Fabric Director allows it.
     
  • An Ethernet port or LAG set to access mode and a vNIC terminating on that Ethernet port or LAG set to trunk mode. This configuration is invalid, but the Fabric Director still allows it.
 
The listed settings are a misconfiguration that can negatively affect the traffic on the VLAN, and can cause hosts to not receive traffic. Be aware that this misconfiguration is not prevented on the Fabric Director, and no error message is displayed if this configuration is specified.

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback