Solution Type Predictive Self-Healing Sure Solution 1528190.1 : Firmware Upgrade Policy and Factory Ship Versions for Oracle Big Data Appliance Sun Fire X4270 M2, X3-2, X4-2,X5-2,X6-2 and X7-2
In this Document
Applies to:Big Data Appliance X3-2 Hardware - Version All Versions and laterBig Data Appliance X6-2 Hardware - Version All Versions and later Big Data Appliance X5-2 Hardware - Version All Versions and later Big Data Appliance X4-2 Hardware - Version All Versions and later Big Data Appliance Hardware - Version All Versions and later Linux x86-64 PurposeDescribe the firmware upgrade policy and factory ship versions on the Oracle Big Data Appliance (BDA) M2, X3-2 and X4-2, X5-2.
Scope
DetailsFirmware Upgrade PolicyReview the Restrictions on Firmware Updates documentation for details. 1. In general customers should not update the firmware of the BDA server components unless instructed to by a MOS Note or by BDA Support. Firmware for BDA server components will be updated during the normal BDA software upgrade process if necessary. The following BDA server components will have their firmware updated during BDA software upgrade if necessary :
2. There is one exception to the above which is that if a faulty server component is replaced and the firmware of the replaced component is at a lower level than what is normally shipped with the BDA then the firmware must be updated. On every server boot the firmware on that server's components will be checked to validate that they are at least at the level shipped by the factory. If the firmware is below the expected version, bdacheckhw will issue an error/warning. For example, the output below shows a HBA (disk controller) firmware discrepency. # bdacheckhw WARNING: Insufficient disk controller firmware minor version : 0048 In case of a an error or warning indicating that the firmware is below the expected version, see Firmware Usage and Upgrade Information for BDA Software Managed Components on Oracle Big Data Appliance V2 (Doc ID 1542871.1), for details on how to resolve this by updating the Firmware. 3. Customers can update the firmware for other components of the BDA rack which are not managed by BDA software patching. Components in this category are:
Note: The recommendation is to update Infiniband switches in BDA racks to at least v2.1.8-1, or preferably the latest tested version v2.2.7-1.
For reference on how to how to check BDA firmware versions see: How to check Big Data Appliance (BDA) firmware versions (Doc ID 2382753.1). bdaupdatefwThe utility bdaupdatefw updates the firmware of a particular component of a server, such as a replacement disk drive. Run it on the command line as root: # bdaupdatefw <parameter>
This utility is typically run by Oracle field engineers when installing or replacing hardware components, which may not be factory-installed with a supported firmware version. During a software installation, the Mammoth Utility copies the currently supported firmware to Oracle Big Data Appliance. The Required Firmware Versions of BDA Software Managed Components X7-2
Firmware Versions of non-BDA Software Managed Components X7-2
Required Firmware Versions of BDA Software Managed Components X6-2
Firmware Versions of non-BDA Software Managed Components X6-2
Required Firmware Versions of BDA Software Managed Components X5-2
Firmware Versions of non-BDA Software Managed Components X5-2
* As per "EIS Installation Checklist for the ORACLE® Big Data Appliance (BDA) X5-2", Due to EIS-ALERT #305 you should also download the “Enhanced” PDU firmware 2.03 available as MOS patch 20917482. Required Firmware Versions of BDA Software Managed Components X4-2
Firmware Versions of non-BDA Software Managed Components X4-2
Required Firmware Versions of BDA Software Managed Components X3-2
Firmware Versions of non-BDA Software Managed Components X3-2
Required Firmware Versions of BDA Software Managed Components Sun Fire X4270 M2
Firmware Versions of non-BDA Software Managed Components Sun Fire X4270 M2