Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1528167.1
Update Date:2016-04-07
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1528167.1 :   Oracle Fabric Interconnect :: MAC Statistics Counters - FCS Error Frames and Jabber Frames  


Related Items
  • Oracle Fabric Interconnect F1-15
  •  
  • Oracle Fabric Interconnect F1-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
  •  




In this Document
Purpose
Details


Applies to:

Oracle Fabric Interconnect F1-15 - Version All Versions to All Versions [Release All Releases]
Oracle Fabric Interconnect F1-4 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Purpose

MAC Statistics Counters show count values for FCS Error Frames and Jabber Frames

Details

When looking through a Oracle Fabric Interconnect 'tech-support' log after gathering diagnostic log bundle by running 'get-log-files -all' script noticed that under "MAC Statistics" there are values for FCS Error Frames and Jabber Frames, what does this mean?
 
Example Output:

## MAC Statistics - slot 14 #############################################################################

port 1 MAC stats:
Rx Octets                         = 319212461789680
Rx Ok Frames                      = 636804242835
Rx Unicast Frames                 = 581439853750
Rx Multicast Frames               = 39280913906
Rx Broadcast Frames               = 16083475179
Rx Ctrl Frames                    = 0
Rx Pause Frames                   = 0
Rx FCS Error Frames               = 8704
Rx Length Error Frames            = 137
Rx Undersize Frames               = 0
Rx Oversize Frames                = 0
Rx Fragment Frames                = 2457
Rx Jabber Frames                  = 29


Replace or reseat the optic cable.  Physical problems with optic cables can cause signal degradation.

FCS and Jabber errors will also be in the xvnd.log.  Customers can run from user 'admin' CLI:

showlog xvnd.log

 Example:

Jan 16 16:23:41 iop-8 xvnd[549]: ERROR: MAC counters error on port 1 RX_JABBER value = 372764
Jan 16 16:24:14 iop-8 xvnd[549]: ERROR: MAC counters error on port 1 RX_JABBER value = 372813
Jan 16 16:24:47 iop-8 xvnd[549]: ERROR: MAC counters error on port 1 RX_JABBER value = 372857
Jan 16 16:25:20 iop-8 xvnd[549]: ERROR: MAC counters error on port 3 RX_JABBER value = 69464
Jan 16 16:25:53 iop-8 xvnd[549]: ERROR: MAC counters error on port 4 RX_JABBER value = 48235
Jan 16 16:33:37 iop-8 xvnd[549]: ERROR: MAC counters error on port 1 RX_JABBER value = 372858
Jan 16 16:34:10 iop-8 xvnd[549]: ERROR: MAC counters error on port 1 RX_JABBER value = 372898
Jan 16 16:34:43 iop-8 xvnd[549]: ERROR: MAC counters error on port 3 RX_JABBER value = 69591

 