Solution Type Predictive Self-Healing Sure Solution 1527200.1 : Configuring Syslog Settings on an Oracle Fabric Interconnect Chassis
In this Document
Applies to:Oracle Fabric Interconnect F1-15 - Version All Versions and laterOracle Fabric Interconnect F1-4 - Version All Versions and later Information in this document applies to any platform. PurposeProvides instructions on how to configure syslog settings on Oracle Fabric Interconnect in order to output Fabric Interconnect logs. DetailsSet the Oracle Fabric Interconnect chassis to logging output to a syslog server as follows: admin@chassis[xsigo] set system syslog-server ?
Possible completions: <name> Hostname or IP address of syslog server admin@chassis[xsigo] set system loglevel ? The command to configure the loglevel level is: admin@f1-4-sc11-a[xsigo] set system loglevel * To set maxium logging: set system loglevel * 7