Configuring Syslog Settings on an Oracle Fabric Interconnect Chassis
| Related Items |
- Oracle Fabric Interconnect F1-15
- Oracle Fabric Interconnect F1-4
|
| Related Categories |
- PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
|
In this Document
Applies to:
Oracle Fabric Interconnect F1-15 - Version All Versions and later
Oracle Fabric Interconnect F1-4 - Version All Versions and later
Information in this document applies to any platform.
Purpose
Provides instructions on how to configure syslog settings on Oracle Fabric Interconnect in order to output Fabric Interconnect logs.
Details
Set the Oracle Fabric Interconnect chassis to logging output to a syslog server as follows:
admin@chassis[xsigo] set system syslog-server ?
Possible completions:
<name> Hostname or IP address of syslog server
To set the syslog levels for chassis logged events, use the following commands:
admin@chassis[xsigo] set system loglevel ?
Possible completions:
VN2::VN2agent
VNIC::VNICAgent
VNIC::VNICManager
VNIC::VNICTestClass
VSSL::SSLAgent
VSSL::SSLManager
VSSL::SSLTester
XT::XTagent
chassis::chassisAgt
chassis::chassisCtr
chassis::chassisMgr
chassis::chassisTestClient
chassis::chassisTestServer
cli::CommandService
diag::DiagService
eventmgr::EventManager
healthmon::HealthMonService
image::ImageManager
ims::IMSService
ims::IMSSlaveService
licensing::LicenseManager
phonehome::PhoneHome
procmon::ProcessMonitor
scd::Sysconfig
snmpcore::Service
statistics::StatsService
sysctl::SystemController
syslogconfig::SyslogRelay
vhba::agent
vhba::manager
vhba::tester
xcm::XCManager
xsm::XSM
xsmp::XSMP
The command to configure the loglevel level is:
admin@f1-4-sc11-a[xsigo] set system loglevel *
Possible completions:
0 XG_LOG_EMERG
1 XG_LOG_ALERT
2 XG_LOG_CRIT
3 XG_LOG_ERR
4 XG_LOG_WARNING
5 XG_LOG_NOTICE
6 XG_LOG_INFO
7 XG_LOG_DEBUG
Repeat '?' for detailed help.
To set maxium logging:
set system loglevel * 7