Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1526318.1
Update Date:2017-09-21
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1526318.1 :   SPT-8001-FR - Ethernet Communication Failure  


Related Items
  • SPARC M5-32
  •  
  • SPARC M7-8
  •  
  • SPARC T7-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M8-8
  •  
  • Oracle SuperCluster M6-32 Hardware
  •  
  • SPARC T7-2
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • SPARC M6-32
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Oracle SuperCluster M6-32 Hardware
SPARC M6-32
SPARC M5-32
SPARC M7-8
SPARC M7-16
Information in this document applies to any platform.

Purpose

 Additional Information for Message ID:  SPT-8001-FR

Details

 

Type: Hardware Fault

          fault.io.ethernet.fail


Severity: Major

Description

A failure has occurred in the system’s internal ethernet communication network.

 

Automated Response
The system will take steps to re-route communication between the service processors.

 

Impact
The system continues to run. Communication between the host and the SP may be lost.

 

Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty component replaced.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.


PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)

Additional Information

No additional information available at this time.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback