Purpose
Additional information for message ID: SPT-8001-92
Details
Type: Hardware Fault
fault.chassis.current.shutdown
Severity: Critical
Description
The electronic circuit breaker on a board has shut off power due to an overcurrent condition.
Automated Response
The system will restart without the affected board in the configuration.
Impact
The system halts and automatically restarts
Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty component replaced.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
Additional Information
No additional information available at this time.