Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1525623.1
Update Date:2015-12-17
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1525623.1 :   SPSUN4V-8001-EP - Memory Buffer-Controller Interconnect CRC Error  


Related Items
  • SPARC M5-32
  •  
  • SPARC M7-8
  •  
  • SPARC T7-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • Oracle SuperCluster M6-32 Hardware
  •  
  • SPARC T7-2
  •  
  • SPARC M6-32
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Oracle SuperCluster M6-32 Hardware
SPARC M6-32
SPARC M7-8
SPARC M7-16
SPARC T7-1
Information in this document applies to any platform.

Purpose

 Additional Information for Message ID:  SPSUN4V-8001-EP

Details

 

Type: Hardware Fault

          fault.memory.memlink-failover-serd


Severity:  Major

Description
A CRC error has occurred in the interconnect between a memory buffer and its memory controller.  While no data has been lost, a lane failover has taken place.

Automated Response
The hardware has automatically reconfigured the link to isolate the failing lane, and successful retransmission of the data has occurred.

Impact
The system's capacity to correct transmission errors between the memory DIMM and its memory controller has been reduced.


Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty component replaced.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.


PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)

Additional Information

No additional information available at this time.