1525612.1
:
SPSUN4V-8001-AD - Switch Chip Uncorrectable Error
Related Items |
- SPARC M5-32
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- Oracle SuperCluster M6-32 Hardware
- SPARC T7-2
- SPARC M6-32
- SPARC M7-16
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
SPARC M5-32
Oracle SuperCluster M6-32 Hardware
SPARC M6-32
SPARC M7-8
SPARC M7-16
Information in this document applies to any platform.
Purpose
Additional Information for Message ID: SPSUN4V-8001-AD
Details
Type: Hardware Fault
fault.asic.switch.chip-uc
Severity: Critical
Description
A switch chip has encountered a chip-level uncorrectable error.
Automated Response
When the system HW restarts, the switch will be deconfigured.
Impact
The system may halt, in which case it will automatically restart.
Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty component replaced.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
Additional Information
No additional information available at this time.