Solution Type  Predictive Self-Healing Sure

Solution  1525607.1 :   SPSUN4V-8001-83 - Unrecoverable CPU to Switch CRC Error.  


Related Items
  • SPARC M5-32
  •  
  • SPARC M7-8
  •  
  • SPARC T7-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • Oracle SuperCluster M6-32 Hardware
  •  
  • SPARC T7-2
  •  
  • SPARC M6-32
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

SPARC M5-32
Oracle SuperCluster M6-32 Hardware
SPARC M6-32
SPARC M7-8
SPARC M7-16
Information in this document applies to any platform.

Purpose

 Additional Information for Message ID:  SPSUN4V-8001-83

Details

 

Type: Hardware Fault

          fault.asic.switch.c2c-uc, fault.cpu.generic-sparc.c2c-uc


Severity: Critical

Description
A chip-to-chip unrecoverable CRC error has occurred between a CPU chip and a switch chip.

Automated Response
The processor may be deconfigured from the system.

Impact
The system halts and automatically restarts.

Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty component replaced.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.


PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)

Additional Information

No additional information available at this time.