Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1524769.1
Update Date:2017-07-07
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1524769.1 :   vsm.LogEvent.Swapp.2500  


Related Items
  • StorageTek Virtual Storage Manager System 6 (VSM6)
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM6
  •  




Applies to:

StorageTek Virtual Storage Manager System 6 (VSM6) - Version All Versions and later
Information in this document applies to any platform.

Purpose

To provide additional information for message ID: vsm.LogEvent.SWapp.2500

Details

vsm.LogEvent.SWapp.2500

Type:

FMS

Severity:

Severe-Moderate

Description

One or more devices has a SAS path problem.

Automated Response

A support file bundle containing debug information will be created.

Impact

A redundant path to one or more devices is down.  This may cause a performance degradation.  If multiple paths are lost then access to customer data may be Lost.

Suggested Action for System Administrators

The description field in the ASR contains the operational and total path counts for each device experiencing a path problem.  And review the support file bundle form ore details.

Note: If ASR (Automatic Service Request) has been enabled for this system, a Service Request should already be initiated. If ASR is not enabled and have a valid service contract please contact VSM6 Support to assist in enabling ASR.