![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1524320.1 : SPT-8001-5S - An unsupported FRU is present in the system.
In this Document
Applies to:SPARC T5-4SPARC T5-2 SPARC T5-8 SPARC T5-1B SPARC M5-32 Information in this document applies to any platform. Purpose
Provide additional information for message ID: SPT-8001-5S Details
Type: Hardware Fault fault.component.invalid Severity: Critical Description An unsupported FRU is present in the system. Automated Response The service-required LED may be illuminated on the affected FRU and chassis. Impact The system will not be allowed to power on until the unsupported FRU is removed. Suggested Action for System Administrator This event is intended to inform the user about a problem that is not typically associated with a fault in the product and does not normally require Oracle Services for resolution. If the system is activated for ASR (Auto Service Request), a service case will not be created by ASR for this event. The administrator should review the ILOM event log for additional information pertaining to this diagnosis, determine which FRU is affected and take action to have the FRU removed. PSH Procedural Article for ILOM-Based Alerts (Doc ID 1155200.1) Attachments This solution has no attachment |
||||||||||||||||
|