Asset ID: |
1-79-1524218.1 |
Update Date: | 2017-09-19 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1524218.1
:
SPSUN4V-8000-VX - Memory CRC correctable errors exceeded acceptable limits
Related Items |
- SPARC M5-32
- SPARC T8-1
- SPARC T8-4
- SPARC M7-8
- SPARC T7-4
- SPARC T5-1B
- Oracle SuperCluster M7 Hardware
- SPARC M8-8
- Oracle SuperCluster M6-32 Hardware
- SPARC T8-2
- SPARC T7-2
- SPARC T5-2
- Oracle SuperCluster M8 Hardware
- SPARC M7-16
- SPARC T7-1
- SPARC T5-4
- SPARC M6-32
- SPARC T5-8
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
SPARC T7-4
Information in this document applies to any platform.
Purpose
Additional Information for Message ID: SPSUN4V-8000-VX
Details
Type: Hardware Fault
fault.memory.memlink-reinit
Severity: Major
Description
Recoverable CRC errors have occurred in the interconnect between a memory buffer and its memory controller. No data has been lost.
Automated Response
The system has recovered from the CRC errors.
Impact
System performance may be impacted by a slight reduction in effective memory bandwidth.
Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty component replaced.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
Additional Information
No additional information available at this time.
Attachments
This solution has no attachment