Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1524200.1
Update Date:2015-12-17
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1524200.1 :   SPSUN4V-8000-SC - Addressing error  


Related Items
  • SPARC M5-32
  •  
  • SPARC M7-8
  •  
  • SPARC T7-4
  •  
  • SPARC T5-1B
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • Oracle SuperCluster M6-32 Hardware
  •  
  • SPARC T7-2
  •  
  • SPARC T5-2
  •  
  • SPARC T5-4
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
  • SPARC M6-32
  •  
  • SPARC T5-8
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

SPARC T5-4
SPARC T5-8
SPARC M7-8
SPARC M7-16
SPARC T7-1
Information in this document applies to any platform.

Purpose

 Additional Information for Message ID: SPSUN4V-8000-SC

Details

 

Type: Hardware Fault

          fault.memory.addr-par

Severity: Critical

Description
An addressing error was detected during an access to system memory.

Automated Response
When the host HW restarts, the affected memory will be removed from the configuration.

Impact
The host HW will crash and restart.

Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty component replaced.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.


PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback