Solution Type  Predictive Self-Healing Sure

Solution  1523800.1 :   What are the Pin Outs for Serial Management Port (Serial Port 1) on the Management Module?  


Related Items
  • Oracle Fabric Interconnect F1-15
  •  
  • Oracle Fabric Interconnect F1-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
  •  




In this Document
Purpose
Details


Applies to:

Oracle Fabric Interconnect F1-4 - Version All Versions to All Versions [Release All Releases]
Oracle Fabric Interconnect F1-15 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Purpose

 Learn what the pin outs are for the serial management port (Serial Port 1) on the management module in Oracle Fabric Interconnects.

Details

Here are the pin outs of the serial management port (Serial Port 1) on the management module.

Oracle Fabric Interconnect (formerly Xsigo) Management Port RJ-45 to DB-9 Converter


RJ 45 Pin Signal Name DB-9 Pin DB-9 Signal Name
=========================================================
1 (blue) RTS 8 What are the pinouts for serial management port (Serial Port 1) on the management module? CTS
2 (orange) DTR 6 DSR
3 (black) TXD 2 RXD
4 (red) GND 5 GND
5 (green) DCD 1 DCD
6 (yellow) RXD 3 TXD
7 (brown) DSR 4 DTR
8 (white) CTS 7 RTS

 


This is identical to the Cisco console rollover cable used by Cisco switches and routers.

 