![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1522875.1 : SPSUN4V-8000-QY - DRAM correctable errors exceeded acceptable limits
In this Document
Applies to:SPARC M6-32SPARC M7-8 Oracle SuperCluster M6-32 Hardware SPARC M7-16 SPARC T7-1 Information in this document applies to any platform. PurposeAdditional Information for Message ID: SPSUN4V-8000-QY Details
Type Fault (fault.memory.dq-ss) Severity Minor Description Correctable errors are coming from a range of addresses within a given DRAM Automated Response The memory controller will be programmed to remap the layout of data in the affected DIMM Impact Hardware will continue to run. Suggested Action for System Administrator . T5, M5, and M6 systems no repair action is recommended, however, for all other systems (T7, M7) the faulty DIMM should be replaced. If the system is connected via the Automated Service Request [ASR] interface, a service request should be automatically generated. However if necessary, refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required. PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1) Details There is no more information available at this time. Attachments This solution has no attachment |
||||||||||||||||
|