![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1522859.1 : SPSUN4V-8000-NH - Chip-Chip recoverable errors exceed limits
In this Document
Applies to:SPARC T5-2SPARC T5-4 SPARC T5-8 Oracle SuperCluster M6-32 Hardware SPARC M6-32 Information in this document applies to any platform. PurposeAdditional information for Message ID: SPSUN4V-8000-NH Details
Type Hardware Fault (fault.cpu.generic-sparc.c2c-reinit) Severity Major Description The number of chip-to-chip recoverable errors has exceeded acceptable levels. Automated Response The processor or links between the processors may be deconfigured from the system. Impact System performance may be affected. Suggested Action for System Administrator . The administrator should arrange to have the FRU containing the faulty component replaced.
Details There is no additional information available at this time. Attachments This solution has no attachment |
||||||||||||||||
|