![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1522829.1 : SPSUN4V-8000-KA - Memory interconnect correctable errors exceeded acceptable limits
In this Document
Applies to:SPARC M5-32SPARC T5-1B SPARC T5-2 SPARC T5-4 SPARC T5-8 Information in this document applies to any platform. PurposeAdditional Information for Message ID: SPSUN4V-8000-KA Details
Type Hardware Fault (fault.memory.board) Severity Major Description The number of correctable errors associated with the interconnect between the memory buffer and one or more DIMMs has exceeded acceptable levels. Automated Response The HW will correct the errors. Impact The Hardware will continue to run. Suggested Action for System Administrator The administrator should arrange to have the FRU containing the faulty component replaced.
Details There is no more information available at this time. Attachments This solution has no attachment |
||||||||||||||||
|