![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1522824.1 : SPSUN4V-8000-DE -- Memory DRAM data pin correctable errors
In this Document
Applies to:SPARC M5-32Oracle SuperCluster M6-32 Hardware SPARC M6-32 SPARC T5-1B SPARC T5-2 Information in this document applies to any platform. PurposeAdditional Information for Message ID: SPSUN4V-8000-DE Details
Memory DRAM data pin correctable errors Fault Hardware Fault (fault.memory.dq) Severity Minor Description Excessive correctable errors are coming from a range of addresses within a given DRAM. Automated Response The memory controller will be programmed to remap the layout of data in the affected DIMM. Impact Hardware will continue to run. Suggested Action for System Administrator For the T5, M5, and M6 systems no repair action is recommended, however for all other systems (T7, M7, etc) the faulty DIMM should be replaced. If the system is connected via the Automated Service Request [ASR] interface, a service request should be automatically generated. However if necessary, refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required. PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1) Details There is no more information available at this time. Attachments This solution has no attachment |
||||||||||||||||
|