Asset ID: |
1-79-1522791.1 |
Update Date: | 2017-09-19 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1522791.1
:
SPSUN4V-8000-W2 - Memory link unrecoverable error
Related Items |
- SPARC M5-32
- SPARC T8-1
- SPARC T8-4
- SPARC T7-4
- SPARC M7-8
- SPARC T5-1B
- Oracle SuperCluster M7 Hardware
- SPARC M8-8
- Oracle SuperCluster M6-32 Hardware
- SPARC T8-2
- SPARC T7-2
- SPARC T5-2
- Oracle SuperCluster M8 Hardware
- SPARC M6-32
- SPARC M7-16
- SPARC T7-1
- SPARC T5-4
- SPARC T5-8
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
SPARC T7-2
SPARC T7-4
Oracle SuperCluster M6-32 Hardware
SPARC M6-32
SPARC M7-8
Information in this document applies to any platform.
Purpose
Additional Information for Message ID: SPSUN4V-8000-W2
Details
Type: Hardware Fault
fault.memory.memlink-uc
Severity: Critical
Description
A problem was detected in the interconnect between a memory buffer and its memory controller.
Automated Response
If the problem occurs during a subsequent system reboot, associated memory DIMMs may be deconfigured.
Impact
This fault may cause a system panic or user process termination, with resulting interruption in service. System performance may be affected.
Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty component replaced.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
Attachments