Asset ID: |
1-79-1522789.1 |
Update Date: | 2017-09-19 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1522789.1
:
SPSUN4V-8000-H5 - Memory module errors exceeded limits
Related Items |
- SPARC M5-32
- SPARC T8-1
- SPARC T8-4
- SPARC T5-1B
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- Oracle SuperCluster M6-32 Hardware
- SPARC T8-2
- SPARC T5-2
- SPARC T7-2
- SPARC T5-4
- SPARC M6-32
- SPARC M7-16
- SPARC T7-1
- SPARC T5-8
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
SPARC M5-32
SPARC T5-8
SPARC T5-1B
SPARC T5-4
SPARC T5-2
Information in this document applies to any platform.
Purpose
Additional Information for Message ID: SPSUN4V-8000-H5
Details
Type
Fault
fault.memory.page
Severity
Minor
Description
The Message ID: SPSUN4V-8000-H5 indicates the Fault Management System has received reports that correctable memory errors attributed to a single page of physical memory being detected. Diagnosis applied to the error reports has determined that a fault is present, although no repair action is needed at this time. No data has been lost. If and when the Solaris Fault Manager determines that there is sufficient cause, service action will be recommended at that time.
Automated Response
An attempt will be made to remove the affected page of memory from service.
There will be no notification.
Impact
The performance of the system may be minimally impacted.
Suggested Action for System Administrator
This is a non-serviceable fault, and no action should be taken.
Attachments
This solution has no attachment