Asset ID: |
1-79-1522787.1 |
Update Date: | 2017-09-19 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1522787.1
:
SPSUN4V-8000-GX - Memory link lane failover
Related Items |
- SPARC M5-32
- SPARC T8-1
- SPARC T8-4
- SPARC T5-1B
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC M8-8
- Oracle SuperCluster M6-32 Hardware
- SPARC T8-2
- SPARC T5-2
- SPARC T7-2
- Oracle SuperCluster M8 Hardware
- SPARC T5-4
- SPARC M6-32
- SPARC M7-16
- SPARC T7-1
- SPARC T5-8
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
SPARC T5-4
Oracle SuperCluster M6-32 Hardware
SPARC M6-32
SPARC T5-8
SPARC T5-1B
Information in this document applies to any platform.
Purpose
Additional Information for Message ID: SPSUN4V-8000-GX
Details
Type: Hardware Fault
fault.memory.memlink-failover
Severity: Major
Description
A CRC error has occurred in the interconnect between a memory buffer and its memory controller. Successful retransmission of the data has occurred.
Automated Response
The hardware has automatically reconfigured the link to isolate the failing lane.
Impact
No data has been lost. The system's capacity to correct transmission errors between the memory DIMM and its memory controller has been reduced.
Suggested Action for System Administrator
At a convenient time, schedule a repair procedure to replace the FRU containing the affected resource.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
Attachments
This solution has no attachment