Predictive Self-Healing Sure
Solution
1522784.1
:
SPSUN4V-8000-F2 - Memory link recoverable CRC errors exceeded acceptable levels
Related Items |
- SPARC M5-32
- SPARC T8-1
- SPARC T8-4
- SPARC T5-1B
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC M8-8
- Oracle SuperCluster M6-32 Hardware
- SPARC T8-2
- SPARC T5-2
- SPARC T7-2
- Oracle SuperCluster M8 Hardware
- SPARC M6-32
- SPARC T5-4
- SPARC M7-16
- SPARC T7-1
- SPARC T5-8
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
SPARC M5-32
SPARC T5-1B
Oracle SuperCluster M6-32 Hardware
SPARC M6-32
SPARC T5-2
Information in this document applies to any platform.
Purpose
Additional Information for Message ID: SPSUN4V-8000-F2
Details
Type: Hardware Fault
fault.memory.memlink
Severity: Major
Description
Recoverable CRC errors have occurred in the interconnect between a memory buffer and its memory controller. The number of CRC errors associated with this memory buffer-controller pair has exceeded acceptable levels.
Automated Response
The system has recovered from the CRC errors.
Impact
No data has been lost. System performance may be impacted by a slight reduction in effective memory bandwidth.
Suggested Action for System Administrator
At a convenient time, schedule a repair procedure to replace FRU containing the affected resource.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)