SPSUN4V-8000-84 - Chip-level uncorrectable error encountered.
Related Items |
- SPARC M5-32
- SPARC T8-1
- SPARC T8-4
- SPARC T5-1B
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC M8-8
- Oracle SuperCluster M6-32 Hardware
- SPARC T8-2
- SPARC T7-2
- SPARC T5-2
- Oracle SuperCluster M8 Hardware
- SPARC T5-4
- SPARC M6-32
- SPARC M7-16
- SPARC T7-1
- SPARC T5-8
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Oracle SuperCluster M6-32 Hardware
SPARC T5-8
SPARC M5-32
SPARC T5-1B
SPARC T5-2
Information in this document applies to any platform.
Purpose
Additional information for Message ID: SPSUN4V-8000-84
Details
Type: Hardware Fault
fault.cpu.generic-sparc.chip-uc
Severity: Critical
Description
This processor has encountered a chip-level uncorrectable error.
Automated Response
The system will attempt to retire all strands in this processor.
Note. The last strand in any OS instance will not be retired. Nor will other functions of the processor be retired (memory controller, IO, networking).
Impact
System performance will be affected. This fault may cause a system panic or user process termination, with resulting interruption in service.
Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty processor replaced.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)