Asset ID: |
1-79-1522731.1 |
Update Date: | 2017-09-19 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1522731.1
:
SPSUN4V-8000-AC -- Core-level uncorrectable error encountered
Related Items |
- SPARC M5-32
- SPARC T8-1
- SPARC T8-4
- SPARC M7-8
- SPARC T7-4
- SPARC T5-1B
- Oracle SuperCluster M7 Hardware
- SPARC M8-8
- Oracle SuperCluster M6-32 Hardware
- SPARC T8-2
- SPARC T7-2
- SPARC T5-2
- Oracle SuperCluster M8 Hardware
- SPARC M6-32
- SPARC M7-16
- SPARC T7-1
- SPARC T5-4
- SPARC T5-8
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Oracle SuperCluster M6-32 Hardware
SPARC M6-32
SPARC M7-8
SPARC M7-16
SPARC T7-1
Information in this document applies to any platform.
Purpose
Additional Information for Message ID: SPSUN4V-8000-AC
Details
Type: Hardware Fault
fault.cpu.generic-sparc.core-uc
Severity: Critical
Description
A processor core has encountered an uncorrectable error.
Automated Response
The fault manager will attempt to remove all strands associated with this processor core from service.
Impact
System performance may be affected. This fault may cause a system panic or user process termination, with resulting interruption in service.
The physical strand numbers of the faulty processor core reported by the fault manager (fmadm faulty) may not be the same as the logical strand numbers reported by Solaris (psrinfo).
Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty processor replaced.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
Attachments
This solution has no attachment