Asset ID: |
1-79-1522729.1 |
Update Date: | 2017-09-19 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1522729.1
:
SPSUN4V-8000-9R - Single core correctable errors exceeded acceptable levels
Related Items |
- SPARC M5-32
- SPARC T8-1
- SPARC T8-4
- SPARC T5-1B
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC M8-8
- Oracle SuperCluster M6-32 Hardware
- SPARC T8-2
- SPARC T5-2
- SPARC T7-2
- Oracle SuperCluster M8 Hardware
- SPARC T5-4
- SPARC M6-32
- SPARC M7-16
- SPARC T7-1
- SPARC T5-8
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
SPARC M5-32
SPARC T5-1B
SPARC T5-2
SPARC T5-4
SPARC T5-8
Information in this document applies to any platform.
Purpose
Additional Information for Message ID: SPSUN4V-8000-9R
Details
Type: Hardware Fault
fault.cpu.generic-sparc.core
Severity: Major
Description
The number of correctable errors associated with this core has exceeded acceptable levels.
Automated Response
The fault manager will attempt to remove all strands associated with this processor core from service.
Impact
System performance may be affected. No data has been lost. The strands in the faulty core are being removed from service.
The physical strand numbers reported by the fault manager (fmadm faulty) may not be the same as the logical strand numbers reported by Solaris (psrinfo).
Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty processor core replaced.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
Attachments
This solution has no attachment