Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1522670.1
Update Date:2017-09-19
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1522670.1 :   SPSUN4V-8000-2S - Chip-to-chip recoverable CRC errors exceeded acceptable levels  


Related Items
  • SPARC M5-32
  •  
  • SPARC T8-1
  •  
  • SPARC T8-4
  •  
  • SPARC T5-1B
  •  
  • SPARC M7-8
  •  
  • SPARC T7-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M8-8
  •  
  • Oracle SuperCluster M6-32 Hardware
  •  
  • SPARC T4-2
  •  
  • SPARC T8-2
  •  
  • SPARC T5-2
  •  
  • SPARC T7-2
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • SPARC T5-4
  •  
  • SPARC M6-32
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
  • SPARC T5-8
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

SPARC T5-1B
SPARC M5-32
SPARC T5-2
SPARC T5-4
SPARC T5-8
Information in this document applies to any platform.

Purpose

 Provide additional information for Message ID: SPSUN4V-8000-2S

Details

Type: Hardware Fault

           fault.cpu.generic-sparc.c2c

Severity: Major

Description
The number of chip-to-chip recoverable errors has exceeded acceptable levels.

Automated Response
No automated response.

Impact
System performance may be affected.  No data has been lost.

Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty component replaced.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)

 

NOTE: Sun SPARC T5-x systems without system firmware 9.1.0.b (or later) may experience C2C Link Training Issues that result in the SPSUN4V-8000-2S diagnosis.

Please see document Upgrade Sun SPARC T5-x systems to system firmware 9.1.0.b (or later) to prevent C2C Link Training and PCIe Root Complex related faults (Doc ID  1582207.1)



Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.