![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1522670.1 : SPSUN4V-8000-2S - Chip-to-chip recoverable CRC errors exceeded acceptable levels
In this Document
Applies to:SPARC T5-1BSPARC M5-32 SPARC T5-2 SPARC T5-4 SPARC T5-8 Information in this document applies to any platform. PurposeProvide additional information for Message ID: SPSUN4V-8000-2S DetailsType: Hardware Fault fault.cpu.generic-sparc.c2c PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
NOTE: Sun SPARC T5-x systems without system firmware 9.1.0.b (or later) may experience C2C Link Training Issues that result in the SPSUN4V-8000-2S diagnosis. Please see document Upgrade Sun SPARC T5-x systems to system firmware 9.1.0.b (or later) to prevent C2C Link Training and PCIe Root Complex related faults (Doc ID 1582207.1) Attachments This solution has no attachment |
||||||||||||||||
|