Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1518344.1
Update Date:2016-12-14
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1518344.1 :   How to identify vendor and device id of a pci card from ILOM or ILOM snapshot  


Related Items
  • Sun Fire X4270 Server
  •  
  • Sun Fire X4270 M2 Server
  •  
  • Sun Fire X4170 Server
  •  
  • Sun Netra X4270 Server
  •  
  • Sun Blade X6270 M2 Server Module
  •  
  • Sun Fire X4170 M2 Server
  •  
  • Sun Netra X6270 M2 Server Module
  •  
  • Sun Blade X6270 Server Module
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Server>SN-x64: MISC-SERVER
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>x64 Servers
  •  




In this Document
Purpose
Details


Applies to:

Sun Netra X6270 M2 Server Module - Version All Versions to All Versions [Release All Releases]
Sun Blade X6270 Server Module - Version All Versions to All Versions [Release All Releases]
Sun Blade X6270 M2 Server Module - Version All Versions to All Versions [Release All Releases]
Sun Fire X4170 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Fire X4170 M2 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Purpose

 To identify expansion cards from within the ilom and or snapshot and used in conjuction with 

Sun x86 and x64 Platforms: Matrix of expansion cards (Doc ID 1374659.1)

Sun x86 and x64 Platforms: Matrix of Recognized Device Paths (Doc ID 1277396.1)

Details

 The document i divided into two sections

ILOM 3.1

Pre-ILOM 3.1 (nehalem machines only) using snapshot technique

 

1. For all machines using ILOM 3.1 or later.

from the ILOM CLI

-> show /System/PCI_Devices/Add-on/ -l all

/System/PCI_Devices/Add-on
Targets:
Device_4

Properties:


/System/PCI_Devices/Add-on/Device_4
Targets:

Properties:
part_number = SGX-SAS6-R-INT-Z
description = Sun Storage 6 Gb SAS PCIe RAID HBA, Internal
location = PCIE4 (PCIe Slot 4)
pci_vendor_id = 0x1000
pci_device_id = 0x0079
pci_subvendor_id = 0x1000
pci_subdevice_id = 0x9263

 

you can achieve the same from the ilom webUI

 

 

2. From ILOM 3.0 on nehalem based machine extracting the information from the snapshot

 

** the documents assumes you are familiar with the way to take a snapshot either via the webUI and or ILOM CLI *****

 

You need to take a full ILOM snapshot while the machine is at least on the bios level and then extract it.

If the the system is not powered on to a minimum of the bios/POST level there is no power for the IO bridge chip so we cannot extract the information from the attached cards.

 

Locate a directory called hostdiags and using your favourite editing/viewing tool check the file

 

more hostdiags/@usr@local@bin@hostdiags_info.out

 <snip>

 

PCIe (IOH)
	Root	Active	Width	Speed(Act/Cpbl)	SecBus  SubBus  Bus     DID     VID
	0-ESI	yes	x4	2.5/2.5 GT/s	0       0       
		yes	x4	2.5/2.5 GT/s			0	3406	8086 (Intel Corporation)
	1	yes	x4	5.0/5.0 GT/s	1       6       
		NO	x4	5.0/5.0 GT/s			1	0079	1000 (LSI Logic / Symbios Logic)  <<<<<<<<<<<<<<<
	3-EM4.1	NO
	5-EM4.0	yes	x8	2.5/5.0 GT/s	13      18      
		NO	x8	2.5/5.0 GT/s			13	806C	111D (Integrated Device Technology, Inc.)
		NO	x4	5.0/5.0 GT/s			15	2532	1077 (QLogic Corp.)
		NO	x4	2.5/2.5 GT/s			16	105E	8086 (Intel Corporation)
	7-NEM1	NO
	9-NEM0	NO
ICH
	RID:90
PCIe (ICH)
	Root	Active	Width	Speed(Act/Cpbl)	SecBus  SubBus  Bus     DID     VID
	0	yes	x4	2.5/RSVD GT/s	31      31      
		NO	x4	2.5/2.5 GT/s			31	10C9	8086 (Intel Corporation)

 

 

 

 

 