Purpose
Does Solaris supports HA vNICs and How Many Virtual Resources are Supported per Server
Details
Virtual Resources Supported per Server:
On Solaris server, 8 vNICs and 8 vHBAs per server are supported.
vNICs support:
- A maximum of 8 standalone vNICs.
- Support from IPMP.
- HA vNICs are not supported from the Fabric Director. However, server-based HA vNICs are available natively through the IPMP on the Sun server.
vHBAs support:
- A maximum of 8 standalone vHBAs.
- Connectivity to commonly available Brocade FC switches in fabric-port mode (f-port). NPIV login must be enabled on the FC switch.
- Dynamic LUN discovery is supported in situations when no LUN masking is present and either an RSCN message is sent from the storage target, or a user-initiated rescan occurs on the vHBAs.
- HA vHBAs (multipathing) is not supported.