Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1516698.1
Update Date:2017-08-07
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1516698.1 :   Oracle Fabric Interconnect (Formerly Xsigo) Does Solaris supports HA vNICs and How Many Virtual Resources are Supported per Server  


Related Items
  • Oracle Fabric Interconnect F1-15
  •  
  • Oracle Fabric Interconnect F1-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
  •  




In this Document
Purpose
Details


Applies to:

Oracle Fabric Interconnect F1-4 - Version All Versions to All Versions [Release All Releases]
Oracle Fabric Interconnect F1-15 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Purpose

 Does Solaris supports HA vNICs and How Many Virtual Resources are Supported per Server

Details

Virtual Resources Supported per Server:

On Solaris server, 8 vNICs and 8 vHBAs per server are supported.

vNICs support:

- A maximum of 8 standalone vNICs.

- Support from IPMP.

- HA vNICs are not supported from the Fabric Director. However, server-based HA vNICs are available natively through the IPMP on the Sun server.


vHBAs support:

- A maximum of 8 standalone vHBAs.

- Connectivity to commonly available Brocade FC switches in fabric-port mode (f-port). NPIV login must be enabled on the FC switch.

- Dynamic LUN discovery is supported in situations when no LUN masking is present and either an RSCN message is sent from the storage target, or a user-initiated rescan occurs on the vHBAs.

- HA vHBAs (multipathing) is not supported.