Solution Type Predictive Self-Healing Sure Solution 1515993.1 : vsm.LogEvent.SWapp.100002
In this Document
Applies to:StorageTek Virtual Storage Manager System 6 (VSM6) - Version All Versions and laterInformation in this document applies to any platform. PurposeTo provide additional information for message ID: vsm.LogEvent.SWapp.100002 Detailsvsm.LogEvent.SWapp.100002 Type:FMS Severity:Severe-Moderate DescriptionA SW component failed. Cluster detected failure & will reset node with reboot Automated ResponseThe node encountered a SW failure & performed a reboot in attempt to reset node. ImpactDuring the restart, the surviving node will pick up operational responsibilities. If this is the surviving node the system will attempt to restart. If the restart process is successful “FSC00100004_CLUSTER_FINISHED_STARTING_NODE Cluster has restarted a node after a failure.” will be indicated. Suggested Action for System AdministratorsDiagnostics should be gathered including logs and core files for diagnosis of the failure. Note: If ASR (Automatic Service Request) has been enabled for this system, a Service Request should already be initiated. If ASR is not enabled and have a valid service contract please contact VSM6 Support to assist in enabling ASR.
Attachments This solution has no attachment |
||||||||||||||||||||||||||
|