Definition of Fabric Director Front Panel LED Codes
Related Items |
- Oracle Fabric Interconnect F1-15
- Oracle Fabric Interconnect F1-4
|
Related Categories |
- PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
|
In this Document
Applies to:
Oracle Fabric Interconnect F1-15 - Version All Versions and later
Oracle Fabric Interconnect F1-4 - Version All Versions and later
Information in this document applies to any platform.
Purpose
Definition of Fabric Director Front Panel LED Codes
Details
The figure shown below helps understand the Front Panel LED status codes:
These codes are same for all models of Fabric Director.
1. ID LED and Status LED blinking green indicates Front Panel Card is running diagnostics.
Each board carries bootloader and diagnostic utility (xDiag.bin) in its flash. If enableDiag flag is set to true, diagnostics will run at POST mode.
2. ID LED is off and Status LED blinking indicates that Front Panel Processor is booting
3. ID LED is off and Status LED is solid green indicates the chassis controller process is up and running.
4. ID LED is off and Status LED is solid amber indicates faulty Front Panel.
5. ID LED is solid yellow and Status LED is solid green indicates Fabric Director is UP..........