INTERNAL reference page for Hardware support team for Exadata Database Machine X3-2, X4-2, X3-8 and X4-8 (w/X4-2L) firmware and patches. For V2, X2-2, X2-8 refer to Note 1358327.1. For X5-2, X4-8 (w/X5-2L), X5-8, X6-2 and X6-8 refer to Note 1998905.1.
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Exadata internal only and HW support partners
Applies to:
Exadata X3-8b Hardware - Version All Versions and later Exadata X4-2 Eighth Rack - Version All Versions and later Exadata X3-2 Full Rack - Version All Versions and later Exadata X4-2 Quarter Rack - Version All Versions and later Exadata X4-8 Hardware - Version All Versions and later Information in this document applies to any platform.
Purpose
This document contains the Exadata Database Machine X3-2, X4-2, X3-8 and X4-8 (w/X4-2L) Firmware and Image patch history for Hardware support. For V2, X2-2, X2-8 refer to Note 1358327.1. For X5-2 and X4-8 (w/X5-2L), X5-8, X6-2 and X6-8 refer to Note 1998905.1. For X7-2, X7-8 refer to Note 2318642.1.
Scope
This note only covers Oracle Sun based hardware versions supported directly by Oracle. For support of Oracle Exadata Database Machine V1 based on HP hardware, please contact the GCS EEST team which interfaces with the Hub that receives contracted support from HP for those units.
For Exadata Software assistance, refer to Internal Master Note 1274721.1
Details
Exadata Database Machine Firmware and Image patch history - X3-2, X4-2, X3-8 and X4-8.
Associated documents:
- NOTE 888828.1 Database Machine and Exadata Storage Server 11g Release 2 (11.2) Supported Versions. This is the definitive guide to patches; this Note is intended only to provide supplemental information regarding hardware firmware versions and patch release information intended for hardware support engineers.
- NOTE 1270094.1 for Exadata Critical Issues and associated patches.
- NOTE 1358327.1 for Exadata Database Machine V2, X2-2 and X2-8 Firmware and Image patch history
- NOTE 1998905.1 for Exadata Database Machine X5-2 X4-8 (w/X5-2L), X5-8, X6-2 and X6-8 Firmware and Image patch history
- NOTE 2318642.1 for Exadata Database Machine X7-2 and X7-8 Firmware and Image patch history
- NOTE 2088888.1 How to Update Disk Drive Firmware on Exadata and Recovery Appliance Compute Nodes
About Exadata Patch Releases
All firmware and patches for Exadata DB Machine are controlled and tested by Oracle DB engineering. Any firmware update is delivered and distributed as an Oracle OS image patch, as Exadata has built-in scripts (/opt/oracle.cellos/CheckHWnFWProfile) to check and re-flash the firmware to Exadata specific versions as distributed within the OS patch. The versions qualified are critical on Exadata Storage Servers (cells) that contain customer data so re-flashing is automatic on boot up if there are any inconsistencies or wrong/replaced down revision parts. All firmware images and tools to flash them are locally available within the OS file system and distributed in the image or Oracle patch.
On Storage Cells all firmware updates are done automatically during the next boot after replacement, to the version contained in the image.
On DB nodes, the re-flashing is not automatic on boot up as it considered less critical being each node is in a RAC cluster. The best practice procedure options for updating firmware on Database nodes after parts replacements are:
1. Check with the customer first and if they have a specific version they are using, then ask they use the normal firmware update utility and bits they have to update to that version themselves and help them with how if they need it. A Warning about version validation may show during boot, but it can be safely ignored.
2. If they don't care, check and update to the latest available on the Oracle download site for that part, using normal manual update methods if there is one available. Use the built-in image script to show the versions being checked for by the image:
/opt/oracle.SupportTools/CheckHWnFWProfile -s
A Warning about version validation may show during boot, but it can be safely ignored until the manual update is completed.
3. If there is no version available newer than what the checks are, then use the image bits/utilities to update to the Exadata tested/approved image version manually using the following option similar to what the storage nodes use:
# /opt/oracle.cellos/CheckHWnFWProfile -U /opt/oracle.cellos/iso/cellbits
Due to release cycles on Exadata, Option 2 may be preferred for ILOM/BIOS if there are bug fixes or features not released on Exadata yet. In most cases though Option 3 is the preferred method, as all firmware and tools are readily available as included in the image. Upon HW replacements the Field Engineer should do f/w upgrades such that the system is left in a booted, updated state. Otherwise, updating via regularly released image update patches is the customer's responsibility to download and update image patches, unless they have separately purchased the ACS proactive service offering.
The only exception is Infiniband switch firmware is not contained within the images. This is a separate patch and manual install release via the instructions in the patch readme.
Approved and released Exadata patches can be found at MOS NOTE 888828.1. That note is the definitive guide to patches, this Note is only to provide supplemental information regarding hardware firmware versions.
The Oracle image version can be checked by running the "imageinfo"command, and the history of images patched or updated previously can be seen with "imagehistory" command on one of the Exadata Storage or Database Nodes:
# imageinfo
Kernel version: 2.6.32-400.1.1.el5uek #1 SMP Mon Jun 25 20:25:08 EDT 2012 x86_64 Cell version: OSS_11.2.3.2.0_LINUX.X64_120713 Cell rpm version: cell-11.2.3.2.0_LINUX.X64_120713-1
Active image version: 11.2.3.2.0.120713 Active image activated: 2012-08-13 19:06:23 -0700 Active image status: success Active system partition on device: /dev/md5 Active software partition on device: /dev/md7
About Version Numbering
Exadata images are numbered with 5 digits: A.B.X.Y.Z.
The first two A.B correspond to the primary database release i.e 11.2 (11g) or 12.1 (12c) or 18.1
The third X is the major feature release version.
The fourth Y is the minor feature release version.
The fifth Z is the patch release version.
Note: Starting September 2017, the Oracle Database changed version numbering from 11.x / 12.x to be 18.x based on the year of release.
The tables below are ordered by Version number only. The release date and version number orders may not be consistent. If a new image is deemed necessary to provide patch fixes to an earlier major.minor release version, a patch release version of an image may be released at a date later than the next major.minor feature release version. In these instances, although newer, the patch fix version may not necessarily incorporate all new firmware that the next major.minor feature release versions contain. All listed firmware updates for a patch releases are relative to the original major.minor version of the release where noted, or the previous major.minor.patch release where not noted.
[go to top]
Exadata OS/Firmware Image History for X4-8 (with X4-2L Storage Servers)
Version | Release Date | Patch Downloads | Detail Notes | Firmware versions included |
18.1.5.0.0 |
May 9, 2018 |
27503194 (Cell) 27561908 (DB Linux and OVM domU) 27561909 (DB OVM dom0)
|
MOS Note 2362411.1
Includes security fixes for CVE-2017-5715 (Spectre Variant 2)
|
Updates to 18.1.4.0.0:
- DB X4-8 SW 2.0.1
ILOM 4.0.2.25.b BIOS 29.09.02.00
- Cell X4-2L SW 2.0.1
ILOM 4.0.2.27.a BIOS 26.06.03.00
|
18.1.4.0.0 |
February 1, 2018 |
27347059 (Cell) 27391002 (DB Linux and OVM domU) 27391003 (DB OVM dom0)
|
MOS Note 2348949.1
Includes Critical Linux and Xen security fixes which includes fixes for Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754)
|
Updates to 18.1.3.0.0:
- No new firmware updates additional to 18.1.3.0.0
|
18.1.3.0.0 |
January 4, 2018 |
27203979 (Cell) 27292339 (DB Linux and OVM domU) 27292341 (DB OVM dom0)
|
MOS Note 2341600.1
|
Updates to 18.1.2.0.0:
- No new firmware updates additional to 18.1.2.0.0
|
18.1.2.0.0 |
November 22, 2017 (Re-issued November 29, 2017) |
27062341 (Cell) 27103628 (DB Linux and OVM domU) 27103629 (DB OVM dom0)
|
MOS Note 2324358.1
|
Updates to 18.1.1.0.0:
- No new firmware updates additional to 18.1.1.0.0
|
18.1.1.0.0 |
October 25, 2017 |
26875767 (Cell) 26923500 (DB Linux and OVM domU) 26923501 (DB OVM dom0)
|
MOS Note 2311786.1
|
Updates to 18.1.0.0.0:
- DB X4-8 SW 1.7.1
ILOM 3.2.10.21.a BIOS 29.08.01.00
- Cell X4-2L SW 1.8.0
ILOM 3.2.10.22.a BIOS 26.05.01.00
|
18.1.0.0.0 |
October 3, 2017 |
25342756 (Cell) 26829586 (DB Linux and OVM domU) 26829591 (DB OVM dom0)
|
MOS Note 2288392.1
New major feature image release with feature support for Oracle Database 18.1 with new version numbering scheme based on year of release similar to Oracle Database.
Support for EAEU 8TB disk models as FRU's - See MOS Note 2309387.1 for details.
|
Updates to 12.2.1.1.2:
- IB HCA - CX3 2.35.5532
- Disks -
Hitachi 8TB SAS - PD51 (H7280A520 model) Hitachi 8TB SAS EAEU - C376 (H7280A524 model)
|
12.2.1.1.7 |
May 9, 2018 |
27503198 (Cell) 27561867 (DB Linux and OVM domU) 27561868 (DB OVM dom0)
|
MOS Note 2362410.1
Includes security fixes for CVE-2017-5715 (Spectre Variant 2) and 12.2 support for 8TB disk alternate and EAEU models.
|
Updates to 12.2.1.1.6:
- DB X4-8 SW 2.0.1
ILOM 4.0.2.25.b BIOS 29.09.02.00
- Cell X4-2L SW 2.0.1
ILOM 4.0.2.27.a BIOS 26.06.03.00
- Disks -
Hitachi 8TB SAS - PD51 (H7280A520 model) Hitachi 8TB SAS EAEU - C376 (H7280A524 model)
|
12.2.1.1.6 |
February 1, 2018 |
27351065 (Cell) 27390990 (DB Linux and OVM domU) 27390991 (DB OVM dom0)
|
MOS Note 2348948.1
Includes Critical Linux and Xen security fixes which includes fixes for Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754)
|
Updates to 12.2.1.1.5:
- No new firmware updates additional to 12.2.1.1.5
|
12.2.1.1.5 |
January 4, 2018 |
27203983 (Cell) 27292320 (DB Linux and OVM domU) 27292321 (DB OVM dom0)
|
MOS Note 2341587.1
|
Updates to 12.2.1.1.4:
- No new firmware updates additional to 12.2.1.1.4
|
12.2.1.1.4 |
November 22, 2017 (Re-issued November 28, 2017) |
27032747 (Cell) 27103625 (DB Linux and OVM domU) 27103627 (DB OVM dom0)
|
MOS Note 2324367.1
|
Updates to 12.2.1.1.3:
- No new firmware updates additional to 12.2.1.1.3
|
12.2.1.1.3 |
October 25, 2017 |
26671200 (Cell) 26774227 (DB Linux and OVM domU) 26774228 (DB OVM dom0)
|
MOS Note 2300276.1
|
Updates to 12.2.1.1.2:
- DB X4-8 SW 1.7.1
ILOM 3.2.10.21.a BIOS 29.08.01.00
- Cell X4-2L SW 1.8.0
ILOM 3.2.10.22.a BIOS 26.05.01.00
- Cell X4-2L IB HCA - CX3 2.35.5532
|
12.2.1.1.2 |
July 2017 |
26027495 (Cell) 26151721 (DB Linux and OVM domU) 26151722 (DB OVM dom0)
|
MOS Note 2270791.1
Support for new 8TB disk model FRU.
|
Updates to 12.2.1.1.1:
- DB X4-8 SW1.7.0
ILOM 3.2.10.21 BIOS 29.07.03.00
- Cell X4-2L SW 1.7.0
ILOM 3.2.10.22 BIOS 26.04.01.00
- Disks -
Hitachi 8TB SAS - A374 (H7280B520 model)
|
12.2.1.1.1 |
April 2017 |
25512521 (Cell) 25640941 (DB Linux and OVM domU) 25640948 (DB OVM dom0)
|
MOS Note 2231247.1
|
Updates to 12.2.1.1.0:
- DB X4-8 SW1.6.0
ILOM 3.2.9.25 BIOS 29.07.03.00
- Cell X4-2L SW 1.6.0
ILOM 3.2.9.22 BIOS 26.04.01.00
- Disks -
Hitachi 8TB SAS - PAG1 (H7280A520 model)
|
12.2.1.1.0 |
January 2017 |
21052028 (Cell) 25463013 (DB Linux and OVM domU) 25463019 (DB OVM dom0)
|
MOS Note 2207148.1
New major feature image release with feature support for Oracle Database 12.2c Release 2.
|
Updates to 12.1.2.3.4:
- No new firmware updates additional to 12.1.2.3.4
|
12.1.2.3.7 |
October 25, 2017 |
26739595 (Cell) 26774178 (DB Linux and OVM domU) 26774179 (DB OVM dom0)
|
MOS Note 2305709.1
|
Updates to 12.1.2.3.6:
- DB X4-8 SW 1.7.1
ILOM 3.2.10.21.a BIOS 29.08.01.00
- Cell X4-2L SW 1.8.0
ILOM 3.2.10.22.a BIOS 26.05.01.00
- Cell X4-2L IB HCA - CX3 2.35.5532
|
12.1.2.3.6 |
July 2017 |
26027499 (Cell) 26151718 (DB Linux and OVM domU) 26151719 (DB OVM dom0)
|
MOS Note 2270790.1
Support for new 8TB disk model FRU.
|
Updates to 12.1.2.3.5:
- DB X4-8 SW1.7.0
ILOM 3.2.10.21 BIOS 29.07.03.00
- Cell X4-2L SW 1.7.0
ILOM 3.2.10.22 BIOS 26.04.01.00
- Disks -
Hitachi 8TB SAS - A374 (H7280B520 model)
|
12.1.2.3.5 |
April 2017 |
25509078 (Cell) 25640844 (DB Linux and OVM domU) 25640846 (DB OVM dom0)
|
MOS Note 2231245.1
|
Updates to 12.1.2.3.4:
- DB X4-8 SW1.6.0
ILOM 3.2.9.25 BIOS 29.07.03.00
- Cell X4-2L SW 1.6.0
ILOM 3.2.9.22 BIOS 26.04.01.00
- Disks -
Hitachi 8TB SAS - PAG1 (H7280A520 model)
|
12.1.2.3.4 |
January 2017 |
25031476 (Cell) 25093501 (DB Linux and OVM domU) 25093502 (DB OVM dom0)
|
MOS Note 2203610.1
|
Updates to 12.1.2.3.3:
- DB X4-8 SW1.5.0
ILOM 3.2.8.21 BIOS 29.06.02.00
- Cell X4-2L SW 1.5.0
ILOM 3.2.8.25 BIOS 26.04.01.00
- Cell X4-2L USB - 8GB firmware update for certain Apacer parts
|
12.1.2.3.3 |
December 2016 (161208 label)
November 2016 (161109 label)
October 2016 (161013 label)
|
24441458 (Cell) 24669306 (DB Linux and OVM domU) 24669307 (DB OVM dom0)
|
MOS Note 2181366.1
*** 12.1.2.3.3 was re-spun and re-released in November, primarily for security bug fixes. This was re-spun again in December, not adding any additional firmware. There are no firmware updates specifically for X4-8 w/X4-2L Storage Servers. The specific bug fix list is contained in the README for Patch 24441458.
|
Updates to 12.1.2.3.2:
- DB X4-8 SW1.4.0
ILOM 3.2.7.20.a BIOS 29.06.02.00
- Cell X4-2L SW 1.4.0
ILOM 3.2.7.32.a BIOS 26.03.01.00
|
12.1.2.3.2 |
July 2016 |
23200959 (Cell) 23564643 (DB Linux and OVM domU) 23564644 (DB OVM dom0)
|
MOS Note 2133207.1
|
Updates to 12.1.2.3.1:
- DB X4-8 SW1.3.1
ILOM 3.2.6.20.a BIOS 29.05.03.00
- Cell X4-2L SW 1.3.4
ILOM 3.2.4.74.a BIOS 26.03.01.00
- Disks -
Hitachi 8TB SAS - P9E2 (H7280A520 model) Hitachi 4TB SAS - A3A0
|
12.1.2.3.1 |
April 2016 (Cell image re-issued July 2016) |
24306177 (Cell) 22954700 (DB Linux and OVM domU) 22954703 (DB OVM dom0)
|
MOS Note 2124734.1
Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details. This issue does not apply to X4-8.
|
Updates to 12.1.2.3.0:
- DB X4-8 SW1.3.0
ILOM 3.2.6.20 BIOS 29.05.03.00
- Cell X4-2L SW1.3.3
ILOM 3.2.4.74 BIOS 26.03.01.00
- Flash F80 LSI 13.05.11.1 FDOM UIO6
|
One-off MLR patches |
March 2016
(Withdrawn July 2016)
|
WITHDRAWN - Refer to MOS Notes 2073916.1 and 2115005.1 for details. |
One-off MLR patches for various image releases to address Exadata Critical Issues 1270094.1 EX25 and EX28.
The patches will update the cell and cell rpm version date string (not the image version number or date) and will also update the firmware bundle file and CheckHWnFWProfile check scripts within the image.
These patches were withdrawn in July 2016 due to EX29.
|
Updates to 12.1.2.2.0, 12.1.2.2.1, 12.1.2.3.0:
- Flash F80 LSI 13.05.11.1 FDOM UIO6
|
12.1.2.3.0 |
February 2016 |
21749993 (Cell) 22750145 (DB Linux and OVM domU) 22750142 (DB OVM dom0)
|
MOS Note 2049743.1
|
- DB X4-8 SW1.2.1
ILOM 3.2.4.38.b BIOS 29.04.03.00
- LSI HBA firmware package - 12.12.0-0243
- Disks -
Hitachi 8TB SAS - P901 (H7280A520 model)
|
12.1.2.2.3 |
July 2016 |
23217781 (Cell) 23557378 (DB Linux and OVM domU) 23557379 (DB OVM dom0)
|
MOS Note 2133208.1
|
Updates to 12.1.2.2.2:
- DB X4-8 SW1.3.1
ILOM 3.2.6.20.a BIOS 29.05.03.00
- Cell X4-2L SW 1.3.4
ILOM 3.2.4.74.a BIOS 26.03.01.00
- Disks -
Hitachi 8TB SAS - P9E2 (H7280A520 model) Hitachi 4TB SAS - A3A0
|
12.1.2.2.2 |
April 2016 (Cell image re-issued in July 2016) |
24306258 (Cell) 22929395 (DB Linux and OVM domU) 22929396 (DB OVM dom0)
|
MOS Note 2124710.1
Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details. This issue does not apply to X4-8.
|
Updates to 12.1.2.2.1:
- DB X4-8 SW1.3.0
ILOM 3.2.6.20 BIOS 29.05.03.00
- Cell X4-2L SW1.3.3
ILOM 3.2.4.74 BIOS 26.03.01.00
- Flash F80 LSI 13.05.11.1 FDOM UIO6
|
12.1.2.2.1 |
January 2016 |
22106928 (Cell) 22277123 (DB Linux and OVM domU) 22277124 (DB OVM dom0)
|
MOS Note 2094446.1
No new firmware updates, but additional disk scrubbing for critical issue EX25 was added.
|
Updates to 12.1.2.2.0:
|
12.1.2.2.0 |
September 2015 |
20131726 (Cell) 21825906 (DB Linux and OVM domU) 21825879 (DB OVM dom0)
|
MOS Note 2038073.1
Includes support for 8TB disks, IPv6, ExaCLI utility, patchmgr use for DB node updates.
|
- DB x4-8 SW 1.2.0
ILOM 3.2.4.38 BIOS 29.04.03.00
- Cell X4-2L SW1.3.1
ILOM 3.2.4.48.a BIOS 26.03.01.00
- LSI HBA firmware package - 12.12.0-0229
- Flash F80 - LSI 13.05.11.0 FDOM UIO6
- Disks -
Hitachi 8TB SAS - P554 (H7280A520 model) Hitachi 4TB SAS - A2D2 or M554 (2nd Model) Hitachi 1.2TB SAS - A720
|
12.1.2.1.3 |
October 2015 |
21446295 (Cell) 21821557 (DB Linux and OVM domU) 21821610 (DB OVM dom0)
|
MOS Note 2031447.1
ILOM security fixes.
|
Updates to 12.1.2.1.2:
- DB X4-8 SW 1.2.0
ILOM 3.2.4.38 BIOS 29.04.03.00
- Cell X4-2L SW1.3.1
ILOM 3.2.4.48.a BIOS 26.03.01.00
|
12.1.2.1.2 |
June 2015 |
20748218 (Cell) 21151982 (DB Linux) 21151986 (DB OVM) 16486998 (Latest dbnodeupdate.sh)
|
MOS Note 2014306.1
|
Updates to 12.1.2.1.1:
|
12.1.2.1.1 |
March 2015 |
20240049 (Cell) 20746761 (DB ULN) 16486998 (Latest dbnodeupdate.sh) |
MOS Note 1959143.1
|
Updates to 12.1.2.1.0:
|
12.1.2.1.0 |
December 2014 |
17885582 (Cell) 20170913 (DB ULN) 16486998 (Latest dbnodeupdate.sh) |
MOS Note 1947476.1
Incorporates the latest available firmware for all hardware, including firmware updates.
Note: New X4-8 systems started shipping with X5-2L Storage Servers in December 2014 - see Note 1998905.1 for details of those.
|
- DB x4-8 SW 1.1.0
ILOM 3.2.4.18 BIOS 29.02.04.00
- Cell X4-2L SW1.2.1
ILOM 3.2.4.22.a BIOS 26.02.05.00
- Flash F80 LSI 09.05.43.00 FDOM UIO3
- Disks -
Hitachi 4TB SAS - A2D2 Hitachi 1.2TB SAS - A6C0
|
12.1.1.1.2 |
April 2015 |
20699031 |
MOS Note 1995937.1
|
Updates relative to 12.1.1.1.1 / 11.2.3.3.1:
- Disks -
Hitachi 4TB SAS - A2D2 Hitachi 1.2TB SAS - A6C0
|
12.1.1.1.1 (12c) |
July 2014 |
18084575 |
MOS Note 1667407.1
First 12c version to support Exadata X4-8 DB nodes. Factory default ship image was 11.2.3.3.1 until 12.1.2.1.0.
|
- Same firmware revisions as 11.2.3.3.1
|
11.2.3.3.1 (11g) |
June 2014 |
Original Factory Release |
Original factory release with support for Exadata X4-8 DB nodes.
Incorporates the latest available firmware for all X4-2L Storage Cell hardware.
|
- DB X4-8 SW1.0
ILOM 3.2.2.12 BIOS 29.01.13.00
- Cell X4-2L SW1.1
ILOM 3.1.2.32.b BIOS 26.01.06.03
- IB HCA CX3 2.11.1280
- LSI HBA firmware package 12.12.0-0178
- Flash F80 LSI 09.05.41.00 FDOM UIO1
- Disks -
Hitachi 4TB SAS - A260 Hitachi 1.2TB SAS - A690
|
[go to top]
Exadata OS/Firmware Image History for X3-8
with X2-8 DB Nodes and either X3-2L or X4-2L Storage Servers
Version | Release Date | Patch Downloads | Detail Notes | Firmware versions included |
18.1.5.0.0 |
May 9, 2018 |
27503194 (Cell) 27561908 (DB Linux and OVM domU) 27561909 (DB OVM dom0)
|
MOS Note 2362411.1
Includes security fixes for CVE-2017-5715 (Spectre Variant 2)
|
Updates to 18.1.4.0.0:
- DB X2-8 (x4800m2) SW 2.0.1
ILOM 4.0.2.25.b BIOS 15.06.01.00
- Cell X4-2L SW 2.0.1
ILOM 4.0.2.27.a BIOS 26.06.03.00
- Cell X3-2L SW 2.0.0
ILOM 4.0.2.27 BIOS 18.14.02.00
|
18.1.4.0.0 |
February 1, 2018 |
27347059 (Cell) 27391002 (DB Linux and OVM domU) 27391003 (DB OVM dom0)
|
MOS Note 2348949.1
Includes Critical Linux and Xen security fixes which includes fixes for Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754)
|
Updates to 18.1.3.0.0:
- No new firmware updates additional to 18.1.3.0.0
|
18.1.3.0.0 |
January 4, 2018 |
27203979 (Cell) 27292339 (DB Linux and OVM domU) 27292341 (DB OVM dom0)
|
MOS Note 2341600.1
|
Updates to 18.1.2.0.0:
- No new firmware updates additional to 18.1.2.0.0
|
18.1.2.0.0 |
November 22, 2017 (Re-issued November 29, 2017) |
27062341 (Cell) 27103628 (DB Linux and OVM domU) 27103629 (DB OVM dom0)
|
MOS Note 2324358.1
|
Updates to 18.1.1.0.0:
- No new firmware updates additional to 18.1.1.0.0
|
18.1.1.0.0 |
October 25, 2017 |
26875767 (Cell) 26923500 (DB Linux and OVM domU) 26923501 (DB OVM dom0)
|
MOS Note 2311786.1
|
Updates to 18.1.0.0.0:
- DB X2-8 (x4800m2) SW 1.8.1
ILOM 3.2.10.21.a BIOS 15.05.03.00
- Cell X4-2L SW 1.8.0
ILOM 3.2.10.22.a BIOS 26.05.01.00
- Cell X3-2L SW 1.9.0
ILOM 3.2.10.22.a BIOS 18.13.01.00
- Cell X4-2L IB HCA - CX3 2.35.5532
|
18.1.0.0.0 |
October 3, 2017 |
25342756 (Cell) 26829586 (DB Linux and OVM domU) 26829591 (DB OVM dom0)
|
MOS Note 2288392.1
New major feature image release with feature support for Oracle Database 18.1 with new version numbering scheme based on year of release similar to Oracle Database.
Support for EAEU 8TB disk models as FRU's - See MOS Note 2309387.1 for details.
|
Updates to 12.2.1.1.2:
- Cell X4-2L IB HCA - CX3 2.35.5532
- Disks -
Hitachi 8TB SAS - PD51 (H7280A520 model) Hitachi 8TB SAS EAEU - C376 (H7280A524 model)
|
12.2.1.1.7 |
May 9, 2018 |
27503198 (Cell) 27561867 (DB Linux and OVM domU) 27561868 (DB OVM dom0)
|
MOS Note 2362410.1
Includes security fixes for CVE-2017-5715 (Spectre Variant 2) and 12.2 support for 8TB disk alternate and EAEU models.
|
Updates to 12.2.1.1.6:
- DB X2-8 (x4800m2) SW 2.0.1
ILOM 4.0.2.25.b BIOS 15.06.01.00
- Cell X4-2L SW 2.0.1
ILOM 4.0.2.27.a BIOS 26.06.03.00
- Cell X3-2L SW 2.0.0
ILOM 4.0.2.27 BIOS 18.14.02.00
- Disks -
Hitachi 8TB SAS - PD51 (H7280A520 model) Hitachi 8TB SAS EAEU - C376 (H7280A524 model)
|
12.2.1.1.6 |
February 1, 2018 |
27351065 (Cell) 27390990 (DB Linux and OVM domU) 27390991 (DB OVM dom0)
|
MOS Note 2348948.1
Includes Critical Linux and Xen security fixes which includes fixes for Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754)
|
Updates to 12.2.1.1.5:
- No new firmware updates additional to 12.2.1.1.5
|
12.2.1.1.5 |
January 4, 2018 |
27203983 (Cell) 27292320 (DB Linux and OVM domU) 27292321 (DB OVM dom0)
|
MOS Note 2341587.1
|
Updates to 12.2.1.1.4:
- No new firmware updates additional to 12.2.1.1.4
|
12.2.1.1.4 |
November 22, 2017 (Re-issued November 28, 2017) |
27032747 (Cell) 27103625 (DB Linux and OVM domU) 27103627 (DB OVM dom0)
|
MOS Note 2324367.1
|
Updates to 12.2.1.1.3:
- No new firmware updates additional to 12.2.1.1.3
|
12.2.1.1.3 |
October 25, 2017 |
26671200 (Cell) 26774227 (DB Linux and OVM domU) 26774228 (DB OVM dom0)
|
MOS Note 2300276.1
|
Updates to 12.2.1.1.2:
- DB X2-8 (x4800m2) SW 1.8.1
ILOM 3.2.10.21.a BIOS 15.05.03.00
- Cell X4-2L SW 1.8.0
ILOM 3.2.10.22.a BIOS 26.05.01.00
- Cell X3-2L SW 1.9.0
ILOM 3.2.10.22.a BIOS 18.13.01.00
- Cell X4-2L IB HCA - CX3 2.35.5532
|
12.2.1.1.2 |
July 2017 |
26027495 (Cell) 26151721 (DB Linux and OVM domU) 26151722 (DB OVM dom0)
|
MOS Note 2270791.1
Support for new 8TB disk model FRU.
|
Updates to 12.2.1.1.1:
- DB X2-8 (x4800m2) SW1.8.0
ILOM 3.2.10.21 BIOS 15.05.03.00
- Cell X4-2L SW 1.7.0
ILOM 3.2.10.22 BIOS 26.04.01.00
- Cell X3-2L SW 1.8.0
ILOM 3.2.10.22 BIOS 18.12.01.00
- Disks -
Hitachi 8TB SAS - A374 (H7280B520 model)
|
12.2.1.1.1 |
April 2017 |
25512521 (Cell) 25640941 (DB Linux and OVM domU) 25640948 (DB OVM dom0)
|
MOS Note 2231247.1
|
Updates to 12.2.1.1.0:
- DB X2-8 (x4800m2) SW1.7.0
ILOM 3.2.9.25 BIOS 15.05.03.00
- Cell X4-2L SW 1.6.0
ILOM 3.2.9.22 BIOS 26.04.01.00
- Cell X3-2L SW 1.7.0
ILOM 3.2.9.22 BIOS 18.12.01.00
- Disks -
Hitachi 8TB SAS - PAG1 (H7280A520 model)
|
12.2.1.1.0 |
January 2017 |
21052028 (Cell) 25463013 (DB Linux and OVM domU) 25463019 (DB OVM dom0)
|
MOS Note 2207148.1
New major feature image release with feature support for Oracle Database 12.2c Release 2.
|
Updates to 12.1.2.3.4:
- DB X2-8 (x4800m2) SW1.5.0+
ILOM 3.2.7.22.b r113564 BIOS 15.05.03.00
|
12.1.2.3.7 |
October 25, 2017 |
26739595 (Cell) 26774178 (DB Linux and OVM domU) 26774179 (DB OVM dom0)
|
MOS Note 2305709.1
|
Updates to 12.1.2.3.6:
- DB X2-8 (x4800m2) SW 1.8.1
ILOM 3.2.10.21.a BIOS 15.05.03.00
- Cell X4-2L SW 1.8.0
ILOM 3.2.10.22.a BIOS 26.05.01.00
- Cell X3-2L SW 1.9.0
ILOM 3.2.10.22.a BIOS 18.13.01.00
- Cell X4-2L IB HCA - CX3 2.35.5532
|
12.1.2.3.6 |
July 2017 |
26027499 (Cell) 26151718 (DB Linux and OVM domU) 26151719 (DB OVM dom0)
|
MOS Note 2270790.1
Support for new 8TB disk model FRU.
|
Updates to 12.1.2.3.5:
- DB X2-8 (x4800m2) SW1.8.0
ILOM 3.2.10.21 BIOS 15.05.03.00
- Cell X4-2L SW 1.7.0
ILOM 3.2.10.22 BIOS 26.04.01.00
- Cell X3-2L SW 1.8.0
ILOM 3.2.10.22 BIOS 18.12.01.00
- Disks -
Hitachi 8TB SAS - A374 (H7280B520 model)
|
12.1.2.3.5 |
April 2017 |
25509078 (Cell) 25640844 (DB Linux and OVM domU) 25640846 (DB OVM dom0)
|
MOS Note 2231245.1
|
Updates to 12.1.2.3.4:
- DB X2-8 (x4800m2) SW1.7.0
ILOM 3.2.9.25 BIOS 15.05.03.00
- Cell X4-2L SW 1.6.0
ILOM 3.2.9.22 BIOS 26.04.01.00
- Cell X3-2L SW 1.7.0
ILOM 3.2.9.22 BIOS 18.12.01.00
- Disks -
Hitachi 8TB SAS - PAG1 (H7280A520 model)
|
12.1.2.3.4 |
January 2017 |
25031476 (Cell) 25093501 (DB Linux and OVM domU) 25093502 (DB OVM dom0)
|
MOS Note 2203610.1
|
Updates to 12.1.2.3.3:
- Cell X4-2L SW 1.5.0
ILOM 3.2.8.25 BIOS 26.04.01.00
- Cell X3-2L SW 1.6.0
ILOM 3.2.8.25 BIOS 18.12.01.00
- Cell X4-2L USB - 8GB firmware update for certain Apacer parts
|
12.1.2.3.3 |
December 2016 (161208 label)
November 2016 (161109 label)
October 2016 (161013 label)
|
24441458 (Cell) 24669306 (DB Linux and OVM domU) 24669307 (DB OVM dom0)
|
MOS Note 2181366.1
*** 12.1.2.3.3 was re-spun and re-released in November, primarily for security bug fixes. This was re-spun again in December, not adding any additional firmware. There are no firmware updates specifically for X3-8. The specific bug fix list is contained in the README for Patch 24441458.
|
Updates to 12.1.2.3.2:
- DB X2-8 (x4800m2) SW1.5.0
ILOM 3.2.7.22.a BIOS 15.05.01.00
- Cell X4-2L SW 1.4.0
ILOM 3.2.7.32.a BIOS 26.03.01.00
- Cell X3-2L SW1.5.0
ILOM 3.2.7.32.a BIOS 18.11.05.00
- Disks -
Hitachi 600GB SAS (X3-2L) - A8C0
|
12.1.2.3.2 |
July 2016 |
23200959 (Cell) 23564643 (DB Linux and OVM domU) 23564644 (DB OVM dom0)
|
MOS Note 2133207.1
|
Updates to 12.1.2.3.1:
- DB X2-8 (x4800m2) SW1.4.1
ILOM 3.2.6.22.a BIOS 15.04.01.00
- Cell X4-2L SW1.3.4
ILOM 3.2.4.74.a BIOS 26.03.01.00
- Cell X3-2L SW1.4.5
ILOM 3.2.4.78.a BIOS 18.11.05.00
- Disks -
Hitachi 8TB SAS - P9E2 (H7280A520 model) Hitachi 4TB SAS - A3A0 Hitachi 600GB SAS (X3-2L) - A820
|
12.1.2.3.1 |
April 2016 (Cell image re-issued July 2016) |
24306177 (Cell) 22954700 (DB Linux and OVM domU) 22954703 (DB OVM dom0)
|
MOS Note 2124734.1
Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details. This issue only applies to X3-8 with X3-2L Storage Servers.
|
Updates to 12.1.2.3.0:
- DB X2-8 SW1.4.0
ILOM 3.2.6.22 BIOS 15.04.01.00
- Cell X4-2L SW1.3.3
ILOM 3.2.4.74 BIOS 26.03.01.00
- Cell X3-2L SW1.4.4
ILOM 3.2.4.78 BIOS 18.11.05.00
- Flash -
F80 (X4-2L) - LSI 13.05.11.1 FDOM UIO6 F40 (X3-2L) - LSI 13.05.10.1 FDOM UIO6
- Disks -
Hitachi 600GB SAS (X3-2L) - A820 (Replaced A880 in re-issue)
|
One-off MLR patches |
March 2016
(Withdrawn July 2016)
|
WITHDRAWN - Refer to MOS Notes 2073916.1 and 2115005.1 for details. |
One-off MLR patches for various image releases to address Exadata Critical Issues 1270094.1 EX25 and EX28.
The patches will update the cell and cell rpm version date string (not the image version number or date) and will also update the firmware bundle file and CheckHWnFWProfile check scripts within the image.
These patches were withdrawn in July 2016 due to EX29.
|
Updates to 12.1.2.2.0, 12.1.2.2.1, 12.1.2.3.0:
- Flash -
F80 (X4-2L) - LSI 13.05.11.1 FDOM UIO6 F40 (X3-2L) - LSI 13.05.10.1 FDOM UIO6
- Disks -
Hitachi 600GB SAS (X3-2L) - A880 (Withdrawn)
|
12.1.2.3.0 |
February 2016 |
21749993 (Cell) 22750145 (DB Linux and OVM domU) 22750142 (DB OVM dom0)
|
MOS Note 2049743.1
|
- DB X2-8 SW 1.3.1
ILOM 3.0.16.34.b BIOS 15.02.09.00
- LSI HBA firmware package - 12.12.0-0243
- Disks -
Hitachi 8TB SAS - P901 (H7280A520 model) Hitachi 600GB SAS (X3-2L) - A820
|
12.1.2.2.3 |
July 2016 |
23217781 (Cell) 23557378 (DB Linux and OVM domU) 23557379 (DB OVM dom0)
|
MOS Note 2133208.1
|
Updates to 12.1.2.2.2:
- DB X2-8 (x4800m2) SW1.4.1
ILOM 3.2.6.22.a BIOS 15.04.01.00
- Cell X4-2L SW1.3.4
ILOM 3.2.4.74.a BIOS 26.03.01.00
- Cell X3-2L SW1.4.5
ILOM 3.2.4.78.a BIOS 18.11.05.00
- Disks -
Hitachi 8TB SAS - P9E2 (H7280A520 model) Hitachi 4TB SAS - A3A0 Hitachi 600GB SAS (X3-2L) - A820
|
12.1.2.2.2 |
April 2016 (Cell image re-issued in July 2016) |
24306258 (Cell) 22929395 (DB Linux and OVM domU) 22929396 (DB OVM dom0)
|
MOS Note 2124710.1
Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details. This issue only applies to X3-8 with X3-2L Storage Servers.
|
Updates to 12.1.2.2.1:
- DB X2-8 SW1.4.0
ILOM 3.2.6.22 BIOS 15.04.01.00
- Cell X4-2L SW1.3.3
ILOM 3.2.4.74 BIOS 26.03.01.00
- Cell X3-2L SW1.4.4
ILOM 3.2.4.78 BIOS 18.11.05.00
- Flash -
F80 (X4-2L) - LSI 13.05.11.1 FDOM UIO6 F40 (X3-2L) - LSI 13.05.10.1 FDOM UIO6
- Disks -
Hitachi 600GB SAS (X3-2L) - A820 (Replaced A880 in re-issue)
|
12.1.2.2.1 |
January 2016 |
22106928 (Cell) 22277123 (DB Linux and OVM domU) 22277124 (DB OVM dom0)
|
MOS Note 2094446.1
No new firmware updates, but additional disk scrubbing for critical issue EX25 was added.
|
Updates to 12.1.2.2.0:
|
12.1.2.2.0 |
September 2015 |
20131726 (Cell) 21825906 (DB Linux and OVM domU) 21825879 (DB OVM dom0)
|
MOS Note 2038073.1
Includes support for 8TB disks, IPv6, ExaCLI utility, patchmgr use for DB node updates.
|
- DB X2-8 SW 1.3.0
ILOM 3.0.16.34 BIOS 15.02.08.00
- Cell X4-2L SW1.3.1
ILOM 3.2.4.48.a BIOS 26.03.01.00
- Cell X3-2L SW1.4.2
ILOM 3.2.4.28.b BIOS 18.11.05.00
- LSI HBA firmware package - 12.12.0-0229
- Flash -
F80 (X4-2L) - LSI 13.05.11.0 FDOM UIO6 F40 (X3-2L) - LSI 13.05.10.0 FDOM UIO6
- Disks -
Hitachi 8TB SAS (X3-2L & X4-2L) - P554 (H7280A520 model) Hitachi 4TB SAS (X4-2L) - M554 (2nd Model - X4-2L only) Hitachi 1.2TB SAS (X4-2L) - A720 Hitachi 600GB SAS (X3-2L) - A7E0
|
12.1.2.1.3 |
October 2015 |
21446295 (Cell) 21821557 (DB Linux and OVM domU) 21821610 (DB OVM dom0)
|
MOS Note 2031447.1
ILOM security fixes.
|
Updates to 12.1.2.1.2:
- DB X2-8 SW 1.3.0
ILOM 3.0.16.34 BIOS 15.02.08.00
- Cell X4-2L SW1.3.1
ILOM 3.2.4.48.a BIOS 26.03.01.00
- Cell X3-2L SW1.4.2
ILOM 3.2.4.28.b BIOS 18.11.05.00
|
12.1.2.1.2 |
June 2015 |
20748218 (Cell) 21151982 (DB Linux) 21151986 (DB OVM) 16486998 (Latest dbnodeupdate.sh)
|
MOS Note 2014306.1
|
Updates to 12.1.2.1.1:
|
12.1.2.1.1 |
March 2015 |
20240049 (Cell) 20746761 (DB ULN) 16486998 (Latest dbnodeupdate.sh) |
MOS Note 1959143.1
|
Updates to 12.1.2.1.0:
|
12.1.2.1.0 |
December 2014 |
17885582 (Cell) 20170913 (DB ULN) 16486998 (Latest dbnodeupdate.sh) |
MOS Note 1947476.1
Incorporates the latest available firmware for all hardware, including firmware updates.
|
- DB X2-8 SW1.2.3
ILOM 3.0.16.20.g BIOS 15.02.06.00
- Cell X4-2L SW1.2.1
ILOM 3.2.4.22.a BIOS 26.02.05.00
- Cell X3-2L SW1.3.1
ILOM 3.1.2.44.a BIOS 18.10.04.00
- IB HCA -
DB - CX2 2.11.2014 Cell (X3-2L) - CX2 2.11.2012
- Flash -
F80 (X4-2L) LSI 09.05.43.00 FDOM UIO3 F40 (X3-2L) LSI 09.05.42.00 FDOM UIO3
- Disks -
Hitachi 4TB SAS (X3-2L & X4-2L) - A2D2 Hitachi 3TB SAS (X3-2L) - A6C0 Hitachi 1.2TB SAS (X4-2L) - A6C0 Hitachi 600GB SAS (X3-2L) - A7A0
|
12.1.1.1.2 |
April 2015 |
20699031 |
MOS Note 1995937.1
|
Updates relative to 12.1.1.1.1 / 11.2.3.3.1:
- Disks -
Hitachi 4TB SAS (X3-2L & X4-2L) - A2D2 Hitachi 3TB SAS (X3-2L) - A6C0 Hitachi 1.2TB SAS (X4-2L) - A6C0 Hitachi 600GB SAS (X3-2L) - A7A0
|
12.1.1.1.1 |
July 2014 |
18084575 |
MOS Note 1667407.1
|
- DB X2-8 SW1.2.2
ILOM 3.0.16.20.e BIOS 15.02.05.00
- Cell X4-2L SW1.1
ILOM 3.1.2.32.b BIOS 26.01.06.03
- Cell X3-2L SW1.3.0
ILOM 3.1.2.44 BIOS 18.10.04.00
- Flash -
F80 (X4-2L) LSI 09.05.41.00 FDOM UIO1 F40 (X3-2L) LSI 09.05.40.00 FDOM UIO1
- Disks -
Hitachi 4TB SAS (X3-2L & X4-2L) - A260 Hitachi 3TB SAS (X3-2L) - A690 Hitachi 1.2TB SAS (X4-2L) - A690
|
12.1.1.1.0 (12c) |
December 2013 |
16980054 (Cell) 17997668 (DB) |
MOS Note 1571789.1
Support for Exadata Storage X4-2L Servers (including IB CX3 HCA, 1.2TB and 4TB disks) used in X3-8B.
Incorporates the latest available firmware for all hardware, including firmware updates previously in the one-off firmware-only patch.
Also includes firmware and script tool to patch update InfiniBand switches over the network (not automatic).
Note: 12.1.1.1.0 provides additional features for customers running Oracle 12c database, and would be installed to replace 11.2.3.3.0. These two images released together. Factory ship version was 11.2.3.3.0 or 11.2.3.3.1.
|
- DB X2-8 SW1.2
ILOM 3.0.16.20.c BIOS 15.02.05.00
- Cell X4-2L SW1.0
ILOM 3.1.2.32 BIOS 26.01.06.00
- Cell X3-2L SW1.2.1
ILOM 3.1.2.12.c BIOS 18.04.03.00
- IB HCA -
CX3 (X4-2L) 2.11.1280
- LSI HBA firmware package 12.12.0-0178
- Flash -
F80 (X4-2L) LSI 09.05.33.00 FDOM UI5P F40 (X3-2L) LSI 09.05.34.00 FDOM UI5P
- Disks -
Hitachi 4TB SAS (X3-2L & X4-2L) - A1B2 Hitachi 1.2TB SAS (X4-2L) - A447
|
11.2.3.3.1 (11g) |
June 2014 |
19166601 (Cell) 18876946 (DB ULN) |
MOS Note 1667414.1
Incorporates the latest available firmware for all hardware, including firmware updates.
|
- DB X2-8 SW1.2.2
ILOM 3.0.16.20.e BIOS 15.02.05.00
- Cell X4-2L SW1.1
ILOM 3.1.2.32.b BIOS 26.01.06.03
- Cell X3-2L SW1.3.0
ILOM 3.1.2.44 BIOS 18.10.04.00
- Flash -
F80 (X4-2L) LSI 09.05.41.00 FDOM UIO1 F40 (X3-2L) LSI 09.05.40.00 FDOM UIO1
- Disks -
Hitachi 4TB SAS (X3-2L & X4-2L) - A260 Hitachi 3TB SAS (X3-2L) - A690 Hitachi 1.2TB SAS (X4-2L) - A690
|
11.2.3.3.0 (11g) |
December 2013 |
16278923 (Cell) 17809253 (DB) |
MOS Note 1487339.1
Support for Exadata Storage X4-2L Servers (including IB CX3 HCA, 1.2TB and 4TB disks) used in X3-8B.
Incorporates the latest available firmware for all hardware, including firmware updates previously in the one-off firmware-only patch.
Also includes firmware and script tool to patch update InfiniBand switches over the network (not automatic).
Note: 11.2.3.3.0 is default shipping version intended for customers running Oracle 11g database. 12.1.1.1.0 was released concurrently and provides additional features for customers running Oracle 12c database.
|
- DB X2-8 SW1.2
ILOM 3.0.16.20.c BIOS 15.02.05.00
- Cell X4-2L SW1.0
ILOM 3.1.2.32 BIOS 26.01.06.00
- Cell X3-2L SW1.2.1
ILOM 3.1.2.12.c BIOS 18.04.03.00
- IB HCA -
CX3 (X4-2L) 2.11.1280
- LSI HBA firmware package 12.12.0-0178
- Flash -
F80 (X4-2L) LSI 09.05.33.00 FDOM UI5P F40 (X3-2L) LSI 09.05.34.00 FDOM UI5P
- Disks -
Hitachi 4TB SAS (X3-2L & X4-2L) - A1B2 Hitachi 1.2TB SAS (X4-2L) - A447
|
11.2.3.2.2 |
March 2014 |
17953347 (Cell) 18205376 (DB) |
MOS Note 1608581.1
Incorporates major firmware updates and several other critical fixes previously in various MLR patches.
|
- IB HCA CX2 (DB & Cell X3-2L) 2.11.2010
- LSI HBA firmware package 12.12.0-0178
- Disks -
Hitachi 3TB SAS (X3-2L) - A600 Hitachi 2TB SAS (X3-2L) - A600 Hitachi 600GB SAS (X3-2L) - A780
|
One-off MLR patches |
July - Dec 2013 |
17201499 <WITHDRAWN> |
[WITHDRAWN: Do not use due to Flash firmware 1.27.94 issues; A new MLR for just the LSI HBA firmware (v0175) and other fixes is available, contact Olly Sharwood for details.]
Standalone patch for critical software and firmware bug fixes. Updates software RPMs, and LSI firmware. Applies to 11.2.3.2.1 image only, and does not update the image version, just the RPMs, and firmware.
Note: CheckHWnFWProfile script does not get updated.
|
- LSI HBA firmware package 12.12.0-0172
|
11.2.3.2.1 |
January 2013 |
14522699 (Cell) 16432033 (DB) |
MOS Note 1485475.1
ILOM compatability for x4800m2 RoHS Power Supply FRU.
Write-Back Smart Flash Cache fixes
|
- DB X2-8 SW1.1.2
ILOM 3.0.16.20.b BIOS 15.01.32.00
- LSI HBA firmware package 12.12.0-0140
- Flash F40 (X3-2L) LSI 08.05.01.00 FDOM UI39
- Disks -
Hitachi 3TB SAS (X3-2L) - A310 Hitachi 600GB SAS (X3-2L) - A700
|
11.2.3.2.0 |
September 2012 |
Original Factory Release |
Oracle Linux 5.8 Unbreakable Enterprise Kernel with updates provided by ULN
Oracle DB 11.2.0.2 and 11.2.0.3. Use of the write-back flash cache feature requires 11.2.0.3.9 or later. |
- DB X2-8 SW1.1.1
ILOM 3.0.16.20.a BIOS 15.01.32.00
- Cell x3-2L SW 1.1.0
ILOM 3.1.2.12 r74388 BIOS 18.02.13.00
- IB HCA CX2 2.7.81.30
- LSI HBA firmware package 12.12.0-0079
- Flash F40 (X3-2L) LSI 06.05.10.00 FDOM TI35
- Disks (X3-2L) -
Seagate 600GB SAS - 0B25; Hitachi 600GB SAS - A6C0 Seagate 3TB SAS - 064A; Hitachi 3TB SAS - A142
|
[go to top]
Exadata OS/Firmware Image History for X4-2
Version | Release Date | Patch Downloads | Detail Notes | Firmware versions included |
18.1.5.0.0 |
May 9, 2018 |
27503194 (Cell) 27561908 (DB Linux and OVM domU) 27561909 (DB OVM dom0)
|
MOS Note 2362411.1
Includes security fixes for CVE-2017-5715 (Spectre Variant 2)
|
Updates to 18.1.4.0.0:
- DB X4-2 SW 2.0.1
ILOM 4.0.2.27.a BIOS 25.06.03.00
- Cell X4-2L SW 2.0.1
ILOM 4.0.2.27.a BIOS 26.06.03.00
|
18.1.4.0.0 |
February 1, 2018 |
27347059 (Cell) 27391002 (DB Linux and OVM domU) 27391003 (DB OVM dom0)
|
MOS Note 2348949.1
Includes Critical Linux and Xen security fixes which includes fixes for Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754)
|
Updates to 18.1.3.0.0:
- No new firmware updates additional to 18.1.3.0.0
|
18.1.3.0.0 |
January 4, 2018 |
27203979 (Cell) 27292339 (DB Linux and OVM domU) 27292341 (DB OVM dom0)
|
MOS Note 2341600.1
|
Updates to 18.1.2.0.0:
- No new firmware updates additional to 18.1.2.0.0
|
18.1.2.0.0 |
November 22, 2017 (Re-issued November 29, 2017) |
27062341 (Cell) 27103628 (DB Linux and OVM domU) 27103629 (DB OVM dom0)
|
MOS Note 2324358.1
|
Updates to 18.1.1.0.0:
- No new firmware updates additional to 18.1.1.0.0
|
18.1.1.0.0 |
October 25, 2017 |
26875767 (Cell) 26923500 (DB Linux and OVM domU) 26923501 (DB OVM dom0)
|
MOS Note 2311786.1
|
Updates to 18.1.0.0.0:
- DB X4-2 SW 1.8.0
ILOM 3.2.10.22.a BIOS 25.05.01.00
- Cell X4-2L SW 1.8.0
ILOM 3.2.10.22.a BIOS 26.05.01.00
|
18.1.0.0.0 |
October 3, 2017 |
25342756 (Cell) 26829586 (DB Linux and OVM domU) 26829591 (DB OVM dom0)
|
MOS Note 2288392.1
New major feature image release with feature support for Oracle Database 18.1 with new version numbering scheme based on year of release similar to Oracle Database.
Support for EAEU 8TB disk models as FRU's - See MOS Note 2309387.1 for details.
|
Updates to 12.2.1.1.2:
- IB HCA - CX3 2.35.5532
- Disks -
Hitachi 8TB SAS - PD51 (H7280A520 model) Hitachi 8TB SAS EAEU - C376 (H7280A524 model)
|
12.2.1.1.7 |
May 9, 2018 |
27503198 (Cell) 27561867 (DB Linux and OVM domU) 27561868 (DB OVM dom0)
|
MOS Note 2362410.1
Includes security fixes for CVE-2017-5715 (Spectre Variant 2) and 12.2 support for 8TB disk alternate and EAEU models.
|
Updates to 12.2.1.1.6:
- DB X4-2 SW 2.0.1
ILOM 4.0.2.27.a BIOS 25.06.03.00
- Cell X4-2L SW 2.0.1
ILOM 4.0.2.27.a BIOS 26.06.03.00
- Disks -
Hitachi 8TB SAS - PD51 (H7280A520 model) Hitachi 8TB SAS EAEU - C376 (H7280A524 model)
|
12.2.1.1.6 |
February 1, 2018 |
27351065 (Cell) 27390990 (DB Linux and OVM domU) 27390991 (DB OVM dom0)
|
MOS Note 2348948.1
Includes Critical Linux and Xen security fixes which includes fixes for Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754)
|
Updates to 12.2.1.1.5:
- No new firmware updates additional to 12.2.1.1.5
|
12.2.1.1.5 |
January 4, 2018 |
27203983 (Cell) 27292320 (DB Linux and OVM domU) 27292321 (DB OVM dom0)
|
MOS Note 2341587.1
|
Updates to 12.2.1.1.4:
- No new firmware updates additional to 12.2.1.1.4
|
12.2.1.1.4 |
November 22, 2017 (Re-issued November 28, 2017) |
27032747 (Cell) 27103625 (DB Linux and OVM domU) 27103627 (DB OVM dom0)
|
MOS Note 2324367.1
|
Updates to 12.2.1.1.3:
- No new firmware updates additional to 12.2.1.1.3
|
12.2.1.1.3 |
October 25, 2017 |
26671200 (Cell) 26774227 (DB Linux and OVM domU) 26774228 (DB OVM dom0)
|
MOS Note 2300276.1
|
Updates to 12.2.1.1.2:
- DB X4-2 SW 1.8.0
ILOM 3.2.10.22.a BIOS 25.05.01.00
- Cell X4-2L SW 1.8.0
ILOM 3.2.10.22.a BIOS 26.05.01.00
- IB HCA CX3 2.35.5532
|
12.2.1.1.2 |
July 2017 |
26027495 (Cell) 26151721 (DB Linux and OVM domU) 26151722 (DB OVM dom0)
|
MOS Note 2270791.1
Support for new 8TB disk model FRU.
|
Updates to 12.2.1.1.1:
- DB X4-2 SW 1.7.0
ILOM 3.2.10.22 BIOS 25.04.01.00
- Cell X4-2L SW 1.7.0
ILOM 3.2.10.22 BIOS 26.04.01.00
- Disks -
Hitachi 8TB SAS - A374 (H7280B520 model)
|
12.2.1.1.1 |
April 2017 |
25512521 (Cell) 25640941 (DB Linux and OVM domU) 25640948 (DB OVM dom0)
|
MOS Note 2231247.1
|
Updates to 12.2.1.1.0:
- DB X4-2 SW 1.6.0
ILOM 3.2.9.22 BIOS 25.04.01.00
- Cell X4-2L SW 1.6.0
ILOM 3.2.9.22 BIOS 26.04.01.00
- Disks -
Hitachi 8TB SAS - PAG1 (H7280A520 model)
|
12.2.1.1.0 |
January 2017 |
21052028 (Cell) 25463013 (DB Linux and OVM domU) 25463019 (DB OVM dom0)
|
MOS Note 2207148.1
New major feature image release with feature support for Oracle Database 12.2c Release 2.
|
Updates to 12.1.2.3.4:
- No new firmware updates additional to 12.1.2.3.4
|
12.1.2.3.7 |
October 25, 2017 |
26739595 (Cell) 26774178 (DB Linux and OVM domU) 26774179 (DB OVM dom0)
|
MOS Note 2305709.1
|
Updates to 12.1.2.3.6:
- DB X4-2 SW 1.8.0
ILOM 3.2.10.22.a BIOS 25.05.01.00
- Cell X4-2L SW 1.8.0
ILOM 3.2.10.22.a BIOS 26.05.01.00
- IB HCA CX3 2.35.5532
|
12.1.2.3.6 |
July 2017 |
26027499 (Cell) 26151718 (DB Linux and OVM domU) 26151719 (DB OVM dom0)
|
MOS Note 2270790.1
Support for new 8TB disk model FRU.
|
Updates to 12.1.2.3.5:
- DB X4-2 SW 1.7.0
ILOM 3.2.10.22 BIOS 25.04.01.00
- Cell X4-2L SW 1.7.0
ILOM 3.2.10.22 BIOS 26.04.01.00
- Disks -
Hitachi 8TB SAS - A374 (H7280B520 model)
|
12.1.2.3.5 |
April 2017 |
25509078 (Cell) 25640844 (DB Linux and OVM domU) 25640846 (DB OVM dom0)
|
MOS Note 2231245.1
|
Updates to 12.1.2.3.4:
- DB X4-2 SW 1.6.0
ILOM 3.2.9.22 BIOS 25.04.01.00
- Cell X4-2L SW 1.6.0
ILOM 3.2.9.22 BIOS 26.04.01.00
- Disks -
Hitachi 8TB SAS - PAG1 (H7280A520 model)
|
12.1.2.3.4 |
January 2017 |
25031476 (Cell) 25093501 (DB Linux and OVM domU) 25093502 (DB OVM dom0)
|
MOS Note 2203610.1
|
Updates to 12.1.2.3.3:
- DB X4-2 SW 1.5.0
ILOM 3.2.8.25 BIOS 25.04.01.00
- Cell X4-2L SW 1.5.0
ILOM 3.2.8.25 BIOS 26.04.01.00
- Cell X4-2L USB - 8GB firmware update for certain Apacer parts
|
12.1.2.3.3 |
December 2016 (161208 label)
November 2016 (161109 label)
October 2016 (161013 label)
|
24441458 (Cell) 24669306 (DB Linux and OVM domU) 24669307 (DB OVM dom0)
|
MOS Note 2181366.1
*** 12.1.2.3.3 was re-spun and re-released in November, primarily for security bug fixes. This was re-spun again in December, not adding any additional firmware. There are no firmware updates specifically for X4-2. The specific bug fix list is contained in the README for Patch 24441458.
|
Updates to 12.1.2.3.2:
- DB X4-2 SW1.4.0
ILOM 3.2.7.32.a BIOS 25.03.01.00
- Cell X4-2L SW 1.4.0
ILOM 3.2.7.32.a BIOS 26.03.01.00
|
12.1.2.3.2 |
July 2016 |
23200959 (Cell) 23564643 (DB Linux and OVM domU) 23564644 (DB OVM dom0)
|
MOS Note 2133207.1
|
Updates to 12.1.2.3.1:
- DB X4-2 SW1.3.4
ILOM 3.2.4.72.a BIOS 25.03.01.00
- Cell X4-2L SW 1.3.4
ILOM 3.2.4.74.a BIOS 26.03.01.00
- Disks -
Hitachi 8TB SAS - P9E2 (H7280A520 model) Hitachi 4TB SAS - A3A0
|
12.1.2.3.1 |
April 2016 (Cell image re-issued July 2016) |
24306177 (Cell) 22954700 (DB Linux and OVM domU) 22954703 (DB OVM dom0)
|
MOS Note 2124734.1
Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details. This issue does not apply to X4-2.
|
Updates to 12.1.2.3.0:
- DB X4-2 SW1.3.3
ILOM 3.2.4.72 BIOS 25.03.01.00
- Cell X4-2L SW1.3.3
ILOM 3.2.4.74 BIOS 26.03.01.00
- Flash F80 LSI 13.05.11.1 FDOM UIO6
|
One-off MLR patches |
March 2016
(Withdrawn July 2016)
|
WITHDRAWN - Refer to MOS Notes 2073916.1 and 2115005.1 for details. |
One-off MLR patches for various image releases to address Exadata Critical Issues 1270094.1 EX25 and EX28.
The patches will update the cell and cell rpm version date string (not the image version number or date) and will also update the firmware bundle file and CheckHWnFWProfile check scripts within the image.
These patches were withdrawn in July 2016 due to EX29.
|
- Flash F80 LSI 13.05.11.1 FDOM UIO6
|
12.1.2.3.0 |
February 2016 |
21749993 (Cell) 22750145 (DB Linux and OVM domU) 22750142 (DB OVM dom0)
|
MOS Note 2049743.1
|
- LSI HBA firmware package - 12.12.0-0243
- Disks -
Hitachi 8TB SAS - P901 (H7280A520 model)
|
12.1.2.2.3 |
July 2016 |
23217781 (Cell) 23557378 (DB Linux and OVM domU) 23557379 (DB OVM dom0)
|
MOS Note 2133208.1
|
Updates to 12.1.2.2.2:
- DB X4-2 SW1.3.4
ILOM 3.2.4.72.a BIOS 25.03.01.00
- Cell X4-2L SW 1.3.4
ILOM 3.2.4.74.a BIOS 26.03.01.00
- Disks -
Hitachi 8TB SAS - P9E2 (H7280A520 model) Hitachi 4TB SAS - A3A0
|
12.1.2.2.2 |
April 2016 (Cell image re-issued in July 2016) |
24306258 (Cell) 22929395 (DB Linux and OVM domU) 22929396 (DB OVM dom0)
|
MOS Note 2124710.1
Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details. This issue does not apply to X4-2.
|
Updates to 12.1.2.2.1:
- DB X4-2 SW1.3.3
ILOM 3.2.4.72 BIOS 25.03.01.00
- Cell X4-2L SW1.3.3
ILOM 3.2.4.74 BIOS 26.03.01.00
- Flash F80 LSI 13.05.11.1 FDOM UIO6
|
12.1.2.2.1 |
January 2016 |
22106928 (Cell) 22277123 (DB Linux and OVM domU) 22277124 (DB OVM dom0)
|
MOS Note 2094446.1
No new firmware updates, but additional disk scrubbing for critical issue EX25 was added.
|
Updates to 12.1.2.2.0:
|
12.1.2.2.0 |
September 2015 |
20131726 (Cell) 21825906 (DB Linux and OVM domU) 21825879 (DB OVM dom0)
|
MOS Note 2038073.1
Includes support for 8TB disks, IPv6, ExaCLI utility, patchmgr use for DB node updates.
|
- DB x4-2 SW 1.3.1
ILOM 3.2.4.46.a BIOS 25.03.01.00
- Cell X4-2L SW1.3.1
ILOM 3.2.4.48.a BIOS 26.03.01.00
- LSI HBA firmware package - 12.12.0-0229
- Flash -
F80 - LSI 13.05.11.0 FDOM UIO6
- Disks -
Hitachi 8TB SAS - P554 (H7280A520 model) Hitachi 4TB SAS - A2D2 or M554 (2nd Model) Hitachi 1.2TB SAS - A720
|
12.1.2.1.3 |
October 2015 |
21446295 (Cell) 21821557 (DB Linux and OVM domU) 21821610 (DB OVM dom0)
|
MOS Note 2031447.1
ILOM security fixes.
|
Updates to 12.1.2.1.2:
- DB x4-2 SW 1.3.1
ILOM 3.2.4.46.a BIOS 25.03.01.00
- Cell X4-2L SW1.3.1
ILOM 3.2.4.48.a BIOS 26.03.01.00
|
12.1.2.1.2 |
June 2015 |
20748218 (Cell) 21151982 (DB Linux) 21151986 (DB OVM) 16486998 (Latest dbnodeupdate.sh)
|
MOS Note 2014306.1
|
Updates to 12.1.2.1.1:
|
12.1.2.1.1 |
March 2015 |
20240049 (Cell) 20746761 (DB ULN) 16486998 (Latest dbnodeupdate.sh) |
MOS Note 1959143.1
|
Updates to 12.1.2.1.0:
|
12.1.2.1.0 |
December 2014 |
17885582 (Cell) 20170913 (DB ULN) 16486998 (Latest dbnodeupdate.sh) |
MOS Note 1947476.1
Incorporates the latest available firmware for all hardware, including firmware updates.
|
- DB x4-2 SW 1.2.1
ILOM 3.2.4.20.a BIOS 25.02.05.00
- Cell X4-2L SW1.2.1
ILOM 3.2.4.22.a BIOS 26.02.05.00
- Flash F80 LSI 09.05.43.00 FDOM UIO3
- Disks -
Hitachi 4TB SAS - A2D2 Hitachi 1.2TB SAS - A6C0
|
12.1.1.1.2 |
April 2015 |
20699031 |
MOS Note 1995937.1
|
Updates relative to 12.1.1.1.1 / 11.2.3.3.1:
- Disks -
Hitachi 4TB SAS - A2D2 Hitachi 1.2TB SAS - A6C0
|
12.1.1.1.1 |
July 2014 |
18084575 |
MOS Note 1667407.1
|
- DB X4-2 SW1.1
ILOM 3.1.2.30.b BIOS 25.01.06.03
- Cell X4-2L SW1.1
ILOM 3.1.2.32.b BIOS 26.01.06.03
- Flash -
F80 LSI 09.05.41.00 FDOM UIO1
- Disks -
Hitachi 4TB SAS - A260 Hitachi 1.2TB SAS - A690
|
12.1.1.1.0 (12c) |
December 2013 |
16980054 (Cell) 17997668 (DB) |
MOS Note 1571789.1
Note: 12.1.1.1.0 provides additional features for customers running Oracle 12c database, and would be installed to replace 11.2.3.3.0. These two images released together. Factory ship version was 11.2.3.3.0 and 12.1.1.1.0 would be applied as a patch over the top of 11.2.3.3.0.
|
- DB X4-2 SW1.0
ILOM 3.1.2.30 BIOS 25.01.06.00
- Cell X4-2L SW1.0
ILOM 3.1.2.32 BIOS 26.01.06.00
- IB HCA CX3 2.11.1280
- LSI HBA firmware package 12.12.0-0178
- Flash F80 LSI 09.05.33.00 FDOM UI5P
- Disks -
Hitachi 4TB SAS - A1B2 Hitachi 1.2TB SAS - A447
|
11.2.3.3.1 (11g) |
June 2014 |
19166601 (Cell) 18876946 (DB ULN) |
MOS Note 1667414.1
Incorporates the latest available firmware for all hardware, including firmware updates.
|
- DB X4-2 SW1.1
ILOM 3.1.2.30.b BIOS 25.01.06.03
- Cell X4-2L SW1.1
ILOM 3.1.2.32.b BIOS 26.01.06.03
- Flash -
F80 LSI 09.05.41.00 FDOM UIO1
- Disks -
Hitachi 4TB SAS - A260 Hitachi 1.2TB SAS - A690
|
11.2.3.3.0 (11g) |
December 2013 |
Original Factory Release |
11.2.3.3.0 Original Factory Release.
Support for Exadata X4-2 DB nodes and Exadata Storage X4-2L Servers (including IB CX3 HCA, 1.2TB and 4TB disks).
UEK is default standard, no longer an option for non-UEK.
Note: 11.2.3.3.0 is default shipping version intended for customers running Oracle 11g database. 12.1.1.1.0 was released concurrently and provides additional features for customers running Oracle 12c database.
|
- DB X4-2 SW1.0
ILOM 3.1.2.30 BIOS 25.01.06.00
- Cell X4-2L SW1.0
ILOM 3.1.2.32 BIOS 26.01.06.00
- IB HCA CX3 2.11.1280
- LSI HBA firmware package 12.12.0-0178
- Flash F80 LSI 09.05.33.00 FDOM UI5P
- Disks -
Hitachi 4TB SAS - A1B2 Hitachi 1.2TB SAS - A447
|
[go to top]
Exadata OS/Firmware Image History for X3-2
Version | Release Date | Patch Downloads | Detail Notes | Firmware versions included |
18.1.5.0.0 |
May 9, 2018 |
27503194 (Cell) 27561908 (DB Linux and OVM domU) 27561909 (DB OVM dom0)
|
MOS Note 2362411.1
Includes security fixes for CVE-2017-5715 (Spectre Variant 2)
|
Updates to 18.1.4.0.0:
- DB X3-2 SW 2.0.0
ILOM 4.0.2.27 BIOS 17.14.02.00
- Cell X3-2L SW 2.0.0
ILOM 4.0.2.27 BIOS 18.14.02.00
|
18.1.4.0.0 |
February 1, 2018 |
27347059 (Cell) 27391002 (DB Linux and OVM domU) 27391003 (DB OVM dom0)
|
MOS Note 2348949.1
Includes Critical Linux and Xen security fixes which includes fixes for Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754)
|
Updates to 18.1.3.0.0:
- No new firmware updates additional to 18.1.3.0.0
|
18.1.3.0.0 |
January 4, 2018 |
27203979 (Cell) 27292339 (DB Linux and OVM domU) 27292341 (DB OVM dom0)
|
MOS Note 2341600.1
|
Updates to 18.1.2.0.0:
- No new firmware updates additional to 18.1.2.0.0
|
18.1.2.0.0 |
November 22, 2017 (Re-issued November 29, 2017) |
27062341 (Cell) 27103628 (DB Linux and OVM domU) 27103629 (DB OVM dom0)
|
MOS Note 2324358.1
|
Updates to 18.1.1.0.0:
- No new firmware updates additional to 18.1.1.0.0
|
18.1.1.0.0 |
October 25, 2017 |
26875767 (Cell) 26923500 (DB Linux and OVM domU) 26923501 (DB OVM dom0)
|
MOS Note 2311786.1
|
Updates to 18.1.0.0.0:
- DB X3-2 SW 1.9.0
ILOM 3.2.10.22.a BIOS 17.13.01.00
- Cell X3-2L SW 1.9.0
ILOM 3.2.10.22.a BIOS 18.13.01.00
|
18.1.0.0.0 |
October 3, 2017 |
25342756 (Cell) 26829586 (DB Linux and OVM domU) 26829591 (DB OVM dom0)
|
MOS Note 2288392.1
New major feature image release with feature support for Oracle Database 18.1 with new version numbering scheme based on year of release similar to Oracle Database.
Support for EAEU 8TB disk models as FRU's - See MOS Note 2309387.1 for details.
|
Updates to 12.2.1.1.2:
- Disks -
Hitachi 8TB SAS - PD51 (H7280A520 model) Hitachi 8TB SAS EAEU - C376 (H7280A524 model)
|
12.2.1.1.7 |
May 9, 2018 |
27503198 (Cell) 27561867 (DB Linux and OVM domU) 27561868 (DB OVM dom0)
|
MOS Note 2362410.1
Includes security fixes for CVE-2017-5715 (Spectre Variant 2) and 12.2 support for 8TB disk alternate and EAEU models.
|
Updates to 12.2.1.1.6:
- DB X3-2 SW 2.0.0
ILOM 4.0.2.27 BIOS 17.14.02.00
- Cell X3-2L SW 2.0.0
ILOM 4.0.2.27 BIOS 18.14.02.00
- Disks -
Hitachi 8TB SAS - PD51 (H7280A520 model) Hitachi 8TB SAS EAEU - C376 (H7280A524 model)
|
12.2.1.1.6 |
February 1, 2018 |
27351065 (Cell) 27390990 (DB Linux and OVM domU) 27390991 (DB OVM dom0)
|
MOS Note 2348948.1
Includes Critical Linux and Xen security fixes which includes fixes for Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754)
|
Updates to 12.2.1.1.5:
- No new firmware updates additional to 12.2.1.1.5
|
12.2.1.1.5 |
January 4, 2018 |
27203983 (Cell) 27292320 (DB Linux and OVM domU) 27292321 (DB OVM dom0)
|
MOS Note 2341587.1
|
Updates to 12.2.1.1.4:
- No new firmware updates additional to 12.2.1.1.4
|
12.2.1.1.4 |
November 22, 2017 (Re-issued November 28, 2017) |
27032747 (Cell) 27103625 (DB Linux and OVM domU) 27103627 (DB OVM dom0)
|
MOS Note 2324367.1
|
Updates to 12.2.1.1.3:
- No new firmware updates additional to 12.2.1.1.3
|
12.2.1.1.3 |
October 25, 2017 |
26671200 (Cell) 26774227 (DB Linux and OVM domU) 26774228 (DB OVM dom0)
|
MOS Note 2300276.1
|
Updates to 12.2.1.1.2:
- DB X3-2 SW 1.9.0
ILOM 3.2.10.22.a BIOS 17.13.01.00
- Cell X3-2L SW 1.9.0
ILOM 3.2.10.22.a BIOS 18.13.01.00
|
12.2.1.1.2 |
July 2017 |
26027495 (Cell) 26151721 (DB Linux and OVM domU) 26151722 (DB OVM dom0)
|
MOS Note 2270791.1
Support for new 8TB disk model FRU.
|
Updates to 12.2.1.1.1:
- DB X3-2 SW1.8.0
ILOM 3.2.10.22 BIOS 17.12.01.00
- Cell X3-2L SW 1.8.0
ILOM 3.2.10.22 BIOS 18.12.01.00
- Disks -
Hitachi 8TB SAS - A374 (H7280B520 model)
|
12.2.1.1.1 |
April 2017 |
25512521 (Cell) 25640941 (DB Linux and OVM domU) 25640948 (DB OVM dom0)
|
MOS Note 2231247.1
|
Updates to 12.2.1.1.0:
- DB X3-2 SW1.7.0
ILOM 3.2.9.22 BIOS 17.12.01.00
- Cell X3-2L SW 1.7.0
ILOM 3.2.9.22 BIOS 18.12.01.00
- Disks -
Hitachi 8TB SAS - PAG1 (H7280A520 model)
|
12.2.1.1.0 |
January 2017 |
21052028 (Cell) 25463013 (DB Linux and OVM domU) 25463019 (DB OVM dom0)
|
MOS Note 2207148.1
New major feature image release with feature support for Oracle Database 12.2c Release 2.
|
Updates to 12.1.2.3.4:
- No new firmware updates additional to 12.1.2.3.4
|
12.1.2.3.7 |
October 25, 2017 |
26739595 (Cell) 26774178 (DB Linux and OVM domU) 26774179 (DB OVM dom0)
|
MOS Note 2305709.1
|
Updates to 12.1.2.3.6:
- DB X3-2 SW 1.9.0
ILOM 3.2.10.22.a BIOS 17.13.01.00
- Cell X3-2L SW 1.9.0
ILOM 3.2.10.22.a BIOS 18.13.01.00
|
12.1.2.3.6 |
July 2017 |
26027499 (Cell) 26151718 (DB Linux and OVM domU) 26151719 (DB OVM dom0)
|
MOS Note 2270790.1
Support for new 8TB disk model FRU.
|
Updates to 12.1.2.3.5:
- DB X3-2 SW1.8.0
ILOM 3.2.10.22 BIOS 17.12.01.00
- Cell X3-2L SW 1.8.0
ILOM 3.2.10.22 BIOS 18.12.01.00
- Disks -
Hitachi 8TB SAS - A374 (H7280B520 model)
|
12.1.2.3.5 |
April 2017 |
25509078 (Cell) 25640844 (DB Linux and OVM domU) 25640846 (DB OVM dom0)
|
MOS Note 2231245.1
|
Updates to 12.1.2.3.4:
- DB X3-2 SW1.7.0
ILOM 3.2.9.22 BIOS 17.12.01.00
- Cell X3-2L SW 1.7.0
ILOM 3.2.9.22 BIOS 18.12.01.00
- Disks -
Hitachi 8TB SAS - PAG1 (H7280A520 model)
|
12.1.2.3.4 |
January 2017 |
25031476 (Cell) 25093501 (DB Linux and OVM domU) 25093502 (DB OVM dom0)
|
MOS Note 2203610.1
|
Updates to 12.1.2.3.3:
- DB X3-2 SW1.6.0
ILOM 3.2.8.25 BIOS 17.12.01.00
- Cell X3-2L SW 1.6.0
ILOM 3.2.8.25 BIOS 18.12.01.00
|
12.1.2.3.3 |
December 2016 (161208 label)
November 2016 (161109 label)
October 2016 (161013 label)
|
24441458 (Cell) 24669306 (DB Linux and OVM domU) 24669307 (DB OVM dom0)
|
MOS Note 2181366.1
*** 12.1.2.3.3 was re-spun and re-released in November, primarily for security bug fixes. This was re-spun again in December, not adding any additional firmware. There are no firmware updates specifically for X3-2. The specific bug fix list is contained in the README for Patch 24441458.
|
Updates to 12.1.2.3.2:
- DB X3-2 SW1.5.0
ILOM 3.2.7.32.a BIOS 17.11.05.00
- Cell X3-2L SW 1.5.0
ILOM 3.2.7.32.a BIOS 18.11.05.00
- Disks -
Hitachi 600GB SAS - A8C0 (H7280A520 model)
|
12.1.2.3.2 |
July 2016 |
23200959 (Cell) 23564643 (DB Linux and OVM domU) 23564644 (DB OVM dom0)
|
MOS Note 2133207.1
|
Updates to 12.1.2.3.1:
- DB X3-2 SW1.4.5
ILOM 3.2.4.76.a BIOS 17.11.05.00
- Cell X3-2L SW1.4.5
ILOM 3.2.4.78.a BIOS 18.11.05.00
- Disks -
Hitachi 8TB SAS - P9E2 (H7280A520 model) Hitachi 4TB SAS - A3A0 Hitachi 600GB SAS - A820
|
12.1.2.3.1 |
April 2016 (Cell image re-issued July 2016) |
24306177 (Cell) 22954700 (DB Linux and OVM domU) 22954703 (DB OVM dom0)
|
MOS Note 2124734.1
Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details.
|
Updates to 12.1.2.3.0:
- DB X3-2 SW1.4.4
ILOM 3.2.4.76 BIOS 17.11.05.00
- Cell X3-2L SW1.4.4
ILOM 3.2.4.78 BIOS 18.11.05.00
- Flash F40 LSI 13.05.10.1 FDOM UIO6
- Disks -
Hitachi 600GB SAS - A820 (Replaced A880 in re-issue)
|
One-off MLR patches |
March 2016
(Withdrawn July 2016)
|
WITHDRAWN - Refer to MOS Notes 2073916.1 and 2115005.1 for details. |
One-off MLR patches for various image releases to address Exadata Critical Issues 1270094.1 EX25 and EX28.
The patches will update the cell and cell rpm version date string (not the image version number or date) and will also update the firmware bundle file and CheckHWnFWProfile check scripts within the image.
These patches were withdrawn in July 2016 due to EX29.
|
Updates to 12.1.2.2.0, 12.1.2.2.1, 12.1.2.3.0:
- Flash F40 LSI 13.05.10.1 FDOM UIO6
- Disks -
Hitachi 600GB SAS - A880 (Withdrawn)
|
12.1.2.3.0 |
February 2016 |
21749993 (Cell) 22750145 (DB Linux and OVM domU) 22750142 (DB OVM dom0)
|
MOS Note 2049743.1
|
- LSI HBA firmware package - 12.12.0-0243
- Disks -
Hitachi 8TB SAS - P901 (H7280A520 model) Hitachi 600GB SAS - A820
|
12.1.2.2.3 |
July 2016 |
23217781 (Cell) 23557378 (DB Linux and OVM domU) 23557379 (DB OVM dom0)
|
MOS Note 2133208.1
|
Updates to 12.1.2.2.2:
- DB X3-2 SW1.4.5
ILOM 3.2.4.76.a BIOS 17.11.05.00
- Cell X3-2L SW1.4.5
ILOM 3.2.4.78.a BIOS 18.11.05.00
- Disks -
Hitachi 8TB SAS - P9E2 (H7280A520 model) Hitachi 4TB SAS - A3A0 Hitachi 600GB SAS - A820
|
12.1.2.2.2 |
April 2016 (Cell image re-issued in July 2016) |
24306258 (Cell) 22929395 (DB Linux and OVM domU) 22929396 (DB OVM dom0)
|
MOS Note 2124710.1
Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details.
|
Updates to 12.1.2.2.1:
- DB X3-2 SW1.4.4
ILOM 3.2.4.76 BIOS 17.11.05.00
- Cell X3-2L SW1.4.4
ILOM 3.2.4.78 BIOS 18.11.05.00
- Flash F40 LSI 13.05.10.1 FDOM UIO6
- Disks -
Hitachi 600GB SAS - A820 (Replaced A880 in re-issue)
|
12.1.2.2.1 |
January 2016 |
22106928 (Cell) 22277123 (DB Linux and OVM domU) 22277124 (DB OVM dom0)
|
MOS Note 2094446.1
No new firmware updates, but additional disk scrubbing for critical issue EX25 was added.
|
Updates to 12.1.2.2.0:
|
12.1.2.2.0 |
September 2015 |
20131726 (Cell) 21825906 (DB Linux and OVM domU) 21825879 (DB OVM dom0)
|
MOS Note 2038073.1
Includes support for 8TB disks, IPv6, ExaCLI utility, patchmgr use for DB node updates.
|
- DB X3-2 SW 1.4.2
ILOM 3.2.4.26.b BIOS 17.11.05.00
- Cell X3-2L SW1.4.2
ILOM 3.2.4.28.b BIOS 18.11.05.00
- LSI HBA firmware package - 12.12.0-0229
- Flash F40 LSI 13.05.10.0 FDOM UIO6
- Disks -
Hitachi 8TB SAS - P554 (H7280A520 model) Hitachi 600GB SAS - A7E0
|
12.1.2.1.3 |
October 2015 |
21446295 (Cell) 21821557 (DB Linux and OVM domU) 21821610 (DB OVM dom0)
|
MOS Note 2031447.1
ILOM security fixes.
|
Updates to 12.1.2.1.2:
- DB X3-2 SW 1.4.2
ILOM 3.2.4.26.b BIOS 17.11.05.00
- Cell X3-2L SW1.4.2
ILOM 3.2.4.28.b BIOS 18.11.05.00
|
12.1.2.1.2 |
June 2015 |
20748218 (Cell) 21151982 (DB Linux) 21151986 (DB OVM) 16486998 (Latest dbnodeupdate.sh)
|
MOS Note 2014306.1
|
Updates to 12.1.2.1.1:
|
12.1.2.1.1 |
March 2015 |
20240049 (Cell) 20746761 (DB ULN) 16486998 (Latest dbnodeupdate.sh) |
MOS Note 1959143.1
|
Updates to 12.1.2.1.0:
|
12.1.2.1.0 |
December 2014 |
17885582 (Cell) 20170913 (DB ULN) 16486998 (Latest dbnodeupdate.sh) |
MOS Note 1947476.1
|
- DB x3-2 SW 1.3.1
ILOM 3.1.2.42.a BIOS 17.10.04.00
- Cell X3-2L SW1.3.1
ILOM 3.1.2.44.a BIOS 18.10.04.00
- IB HCA CX2 2.11.2012
- Flash F40 LSI 09.05.42.00 FDOM UIO3
- Disks -
Hitachi 4TB SAS - A2D2 Hitachi 3TB SAS - A6C0 Hitachi 600GB SAS - A7A0
|
12.1.1.1.2 |
April 2015 |
20699031 |
MOS Note 1995937.1
|
- Updates are relative to 12.1.1.1.1 / 11.2.3.3.1
- Disks -
Hitachi 4TB SAS - A2D2 Hitachi 3TB SAS - A6C0 Hitachi 600GB SAS - A7A0
|
12.1.1.1.1 |
July 2014 |
18084575 |
MOS Note 1667407.1
|
- DB X3-2 SW1.3.0
ILOM 3.1.2.42 BIOS 17.10.04.00
- Cell X3-2L SW1.3.0
ILOM 3.1.2.44 BIOS 18.10.04.00
- Flash -
F40 LSI 09.05.40.00 FDOM UIO1
- Disks -
Hitachi 3TB SAS - A690
|
12.1.1.1.0 (12c) |
December 2013 |
16980054 (Cell) 17997668 (DB) |
MOS Note 1571789.1
Incorporates the latest available firmware for all hardware, including firmware updates previously in the one-off firmware-only patch.
Also includes firmware and script tool to patch update InfiniBand switches over the network (not automatic).
Note: 12.1.1.1.0 provides additional features for customers running Oracle 12c database, and would be optionally installed to replace 11.2.x.x.x. This was released concurrently with 11.2.3.3.0.
|
- DB X3-2 SW1.2.1
ILOM 3.1.2.10.c BIOS 17.04.03.00
- Cell X3-2L SW1.2.1
ILOM 3.1.2.12.c BIOS 18.04.03.00
- IB HCA CX2 2.11.2010
- LSI HBA firmware package 12.12.0-0178
- Flash F40 LSI 09.05.34.00 FDOM UI5P
|
11.2.3.3.1 (11g) |
June 2014 |
19166601 (Cell) 18876946 (DB ULN) |
MOS Note 1667414.1
|
- DB X3-2 SW1.3.0
ILOM 3.1.2.42 BIOS 17.10.04.00
- Cell X3-2L SW1.3.0
ILOM 3.1.2.44 BIOS 18.10.04.00
- Flash -
F40 LSI 09.05.40.00 FDOM UIO1
- Disks -
Hitachi 3TB SAS - A690
|
11.2.3.3.0 (11g) |
December 2013 |
16278923 (Cell) 17809253 (DB) |
MOS Note 1487339.1
Minimum version required to support 32GB DIMM upgrades.
Incorporates the latest available firmware for all hardware, including firmware updates previously in the one-off firmware-only patch.
Also includes firmware and script tool to patch update InfiniBand switches over the network (not automatic).
Note: 11.2.3.3.0 was the default version intended for customers running Oracle 11g database. 12.1.1.1.0 was released concurrently and provides additional features for customers running Oracle 12c database.
|
- DB X3-2 SW1.2.1
ILOM 3.1.2.10.c BIOS 17.04.03.00
- Cell X3-2L SW1.2.1
ILOM 3.1.2.12.c BIOS 18.04.03.00
- IB HCA CX2 2.11.2010
- LSI HBA firmware package 12.12.0-0178
- Flash F40 LSI 09.05.34.00 FDOM UI5P
|
11.2.3.2.2 |
March 2014 |
17953347 (Cell) 18205376 (DB) |
MOS Note 1608581.1
Incorporates major firmware updates and several other critical fixes previously in various MLR patches.
|
- IB HCA 2.11.2010
- LSI HBA firmware package 12.12.0-0178
- Disks -
Hitachi 3TB SAS - A600 Hitachi 2TB SAS - A600 Hitachi 600GB SAS - A780
|
One-off MLR patch |
March 2014 |
17878822 |
Standalone patch for LSI firmware to address 'chip pause' issue. Applies to 11.2.3.2.1 image only, and does not update the image version, just the firmware.
|
- LSI HBA firmware package 12.12.0-0178
|
One-off MLR patches |
July - Dec 2013 |
17201499 <WITHDRAWN> |
[WITHDRAWN: Do not use due to Flash firmware 1.27.94 issues; ]
Standalone patch for critical software and firmware bug fixes. Updates software RPMs, and LSI firmware. Applies to 11.2.3.2.1 image only, and does not update the image version, just the RPMs, and firmware.
Note: CheckHWnFWProfile script does not get updated.
|
- LSI HBA firmware package 12.12.0-0172
|
11.2.3.2.1 |
January 2013 |
14522699 (Cell) 16432033 (DB) |
MOS Note 1485475.1
Write-Back Smart Flash Cache fixes
|
- LSI HBA firmware package 12.12.0-0140
- Flash F40 LSI 08.05.01.00 FDOM UI39
- Disks -
Hitachi 3TB SAS - A310 Hitachi 600GB SAS - A700
|
11.2.3.2.0 |
September 2012 |
Original Factory Release |
Oracle Linux 5.8 Unbreakable Enterprise Kernel with updates provided by ULN or Solaris 11 SRU8.5 with updates provided by Oracle support repository.
Oracle DB 11.2.0.2 and 11.2.0.3. Use of the write-back flash cache feature requires 11.2.0.3.9 or later.
This also supports the non-UEK kernel for X3-2 hardware. The non-UEK kernel can be installed by following the steps described in chapter 6.4 in the README for Patch 14212264. Recommended is to use the UEK kernel. |
- DB x3-2 SW 1.1.0
ILOM 3.1.2.10 r74387 BIOS 17.02.13.00
- Cell x3-2L SW 1.1.0
ILOM 3.1.2.12 r74388 BIOS 18.02.13.00
- IB HCA 2.7.81.30
- LSI HBA firmware package 12.12.0-0079
- Disks -
Seagate 600GB SAS - 0B25; Hitachi 600GB SAS - A6C0 Seagate 3TB SAS - 064A; Hitachi 3TB SAS - A142
- Flash F40 LSI 06.05.10.00 FDOM TI35
|
[go to top]
Exadata - Sun Infiniband 36P Data Center Switch Firmware
Note: IB firmware provided with Exadata OS Image patch bundles can be installed using the bundled tools, independent of doing the whole OS Image update, so customer's can choose to qualify and update to the new IB firmware without updating the server's to the latest OS Image at the same time.
Version | Release Date | Patch Downloads | Detail Notes |
2.2.9-3 |
May 9, 2018 |
27503194 |
Provided with Exadata OS Image 18.1.5.0.0 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details.
|
2.2.7-1 |
Oct 2017 |
25342756 |
Provided with Exadata OS Image 18.1.0.0.0 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details.
|
2.2.6-2 |
July 2017 |
26027495 |
Provided with Exadata OS Image 12.2.1.1.2 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details.
|
2.2.5-3 |
April 2017 |
25512521 |
Provided with Exadata OS Image 12.2.1.1.1 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details.
|
2.2.4-3 |
January 2017 |
21052028 |
Provided with Exadata OS Image 12.2.1.1.0 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details.
|
2.1.8-1 |
February 2016 |
21749993 |
Provided with Exadata OS Image 12.1.2.3.0 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details. Minimum supported firmware version for Switch P/N 7305544.
|
2.1.6-2 |
September 2015 |
20131726 or 21446295 |
Provided with Exadata OS Image 12.1.2.2.0 and 12.1.2.1.3 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details.
|
2.1.5-2 |
December 2014 |
17885582 |
Provided with Exadata OS Image 12.1.2.1.0 patch, installed via patchmgr from DB01 - Refer to MOS Note 1947476.1 for specific details.
Requires switch to be on 2.1.3-4 or 1.3.3-2 before upgrading.
|
2.1.3-4 |
December 2013 |
16278923 |
Provided with Exadata OS Image 11.2.3.3.0 patch, installed via patchmgr from DB01 - Refer to MOS Note 1487339.1 for specific details.
ASR support and partitioning support with compatibility to Exalogic/BDA/SSC multi-racked environments (see MOS Note patch for caveats)
|
1.3.3-2 |
April 2011 |
12373676 (Exadata Scripts) 11891229 (Firmware package) |
Resolves issues with the OFED stack that can cause the subnet manager to go offline and not failover which can bring down the IB fabric
Requires v1.1.3-2b to update using ILOM pkg format. |
[go to top]
Exadata - Sun Rack II Power Distribution Unit (PDU) Firmware
Version | Release Date | Patch Downloads | Detail Notes |
2.0.7 |
January 2017 |
25393172 |
Enhanced SR-II PDU firmware (note firmware can only be used on the Enhanced SR-II PDUs, Enhanced PDUs cannot use older firmware V1.x.)
Resolves several bugs including network scan bug fix.
|
2.0.5 |
June 2016 |
23606606 |
Enhanced SR-II PDU firmware (note firmware can only be used on the Enhanced SR-II PDUs, Enhanced PDUs cannot use older firmware V1.x.)
Resolves several bugs including a partial network scan bug fix.
|
2.0.4 |
May 2015 |
21158114 |
Enhanced SR-II PDU firmware (note firmware can only be used on the Enhanced SR-II PDUs, Enhanced PDUs cannot use older firmware V1.x.)
Resolves security fixes.
|
2.0.3 |
April 2015 |
20917482 |
Enhanced SR-II PDU firmware (note firmware can only be used on the Enhanced SR-II PDUs, Enhanced PDUs cannot use older firmware V1.x.)
Resolves issue that requires reset after each set, and security fixes.
|
2.0.2 |
December 2014 |
20191742 |
Enhanced SR-II PDU firmware (note firmware can only be used on the Enhanced SR-II PDUs, Enhanced PDUs cannot use older firmware V1.x.)
|
2.0.1 |
June 2014 |
19057911 |
Enhanced SR-II PDU firmware (note firmware can only be used on the Enhanced SR-II PDUs, Enhanced PDUs cannot use older firmware V1.x.)
Resolves Oracle-RMII::pduSyslogValuesEnabledPdu can be SET to non-valid values using SNMP bug #18928220.
Resolves interfaces access via ethernet sometimes hang bug #18942719.
|
1.0.6 |
January 2013 |
16523441 |
Resolves uptime and periodic resetting Bug 15807516 (Sun: 7188479).
Modifies default 'admin' password to meet Oracle password security requirements (change from 'admin' to 'adm1n')
|
1.0.4 |
August 2011 |
12871297 |
Provides the ability to reset to factory defaults with static IP 192.168.0.1 and all interfaces enabled. This is a fail safe if the customer inadvertently disables html and does not have snmp setup properly to reset it through that. The procedure is to hold down the button for 10-15 seconds until it starts counting down 5 4 3 2 1, then release the button, then while its still counting down, press and hold it down again for 20 seconds. |
[go to top]
Exadata - Cisco Catalyst 4948 / 4948E-F Gigabit Ethernet Switch
The switch comes with Cisco Enterprise Support if under an Oracle Premier Support contract. Support is provided through Oracle TSC Network team with Cisco support agreements for further assistance from Cisco if required. Oracle can provide patch updates to the Cisco Catalyst 4948 (WS-C4948-S) and 4948E (WS-C4948E-F) switch IOS firmware if necessary. Refer to the EIS checklist for later version information.
The version of firmware shipped by Oracle on 4948 and 4948E-F on Exadata X3-2/X3-8's is IPBASEK9 which does include SSH support and is enabled by default out of the factory, with telnet disabled. The original version shipped was 15.0(2) for 4948, however the version that Oracle currently ships may be later than this. As of June 2013, the version shipped for 4948E-F is 15.1(1). The change of model from 4948 to 4948E-F occurred in December 2012. All X4-2 racks only ship the 4948E-F model.
The version and model type can be obtained using the "show version" command.
sw-ip>show version Cisco IOS Software, Catalyst 4500 L3 Switch Software (cat4500-IPBASEK9-M), Version 15.0(2)SG4, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2012 by Cisco Systems, Inc. Compiled Mon 19-Mar-12 15:11 by prod_rel_team Image text-base: 0x10000000, data-base: 0x1208DAFC
ROM: 12.2(31r)SGA2 Dagobah Revision 226, Swamp Revision 5
sw-ip uptime is 8 weeks, 6 days, 22 hours, 36 minutes System returned to ROM by power-on System restarted at 13:06:19 EDT Thu Aug 23 2012 System image file is "bootflash:cat4500-ipbasek9-mz.150-2.SG4.bin"
This product contains cryptographic features and is subject to United States and local country laws governing import, export, transfer and use. Delivery of Cisco cryptographic products does not imply third-party authority to import, export, distribute or use encryption. Importers, exporters, distributors and users are responsible for compliance with U.S. and local country laws. By using this product you agree to comply with applicable laws and regulations. If you are unable to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at: http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to export@cisco.com.
cisco WS-C4948 (MPC8245) processor (revision 0) with 262144K bytes of memory. Processor board ID FOX1532G8N9 MPC8245 CPU at 266Mhz, Fixed Module Last reset from PowerUp 2 Virtual Ethernet interfaces 48 Gigabit Ethernet interfaces 511K bytes of non-volatile configuration memory.
Configuration register is 0x2102 sw-ip>
[go to top]
References<NOTE:2318642.1> - INTERNAL Exadata Database Machine Hardware Firmware and Patch History (X7-2, X7-8) <NOTE:1270094.1> - Exadata Critical Issues <NOTE:888828.1> - Exadata Database Machine and Exadata Storage Server Supported Versions <NOTE:1358327.1> - INTERNAL Exadata Database Machine Hardware Firmware and Patch History (V2, X2-2, X2-8) <NOTE:1998905.1> - INTERNAL Exadata Database Machine Hardware Firmware and Patch History (X5-2, X4-8 w/X5-2L, X5-8, X6-2, X6-8) <NOTE:2088888.1> - How to Update Disk Drive Firmware on Exadata and Recovery Appliance Compute Nodes
Attachments
This solution has no attachment
|