Solution Type Predictive Self-Healing Sure Solution 1496283.1 : Sun 7000 Unified Storage System: ASR Fan Alarm Verification
In this Document
Applies to:Sun ZFS Storage 7420 - Version All Versions and laterSun ZFS Storage 7320 - Version All Versions and later Sun Storage 7110 Unified Storage System - Version All Versions and later Sun Storage 7210 Unified Storage System - Version All Versions and later Sun Storage 7310 Unified Storage System - Version All Versions and later 7000 Appliance OS (Fishworks) PurposeThe purpose of this document is to assist in the troubleshooting of fan related alerts for the 7xx0 Unified Storage Appliances.
DetailsSymptom: Appliance has an amber LED lit for Fan Module / Fan Power Board and (or) an alert was received from the appliance indication that there is a FAN related failure. Resolution: 1. Confirm whether you have one of the following faults via: BUI (Browser User Interface) -> Click MAINTENANCE, PROBLEMS
2. Check the fan to see if it has lost power or there is a physical obstruction.
3. Verify SP version via
If SP <= 2.0.2.5, these versions contain the SP memory leak bug. It is highly possible that you are hitting bug#6869041. SP version 2.0.2.16 fixes the SP memory leak issue. Once SP FW has been updated then verify if the FAN fault persists. Please engage an Oracle Support Engineer (see end of document) to assist with upgrading the SP firmware level 4. Is this a re-occurring failure on this particular FAN location?
5. Engage Support Engineer (see below) to investigate as a systemic issue.
Note: For Sun ZFS Storage 7x20 systems, using the 3.x ILOM version, please be aware of ... CR 7035044 : Exadata x2-2:: S0/G0 ACPI state changes to working for no apparent reason.
( Current rev : 3.0.9.25 ) This bug is also known to lead to 'false' reporting of PSU/FAN failures.
Engaging a Support Engineer Please update your SR if the proposed solution did not fix the issue, a support engineer will then be assigned to assist. Without further updates we will close this SR in 14 days. References<NOTE:1324444.1> - Sun Storage 7000 Unified Storage System: Fan TroubleshootingAttachments This solution has no attachment |
||||||||||||||||
|