Solution Type  Predictive Self-Healing Sure

Solution  1490956.1 :   CPU / Memory Dimm Map Sun Fire V440, Sun Fire V445 and Netra 440  


Related Items
  • Sun Fire V440 Server
  •  
  • Sun Fire V445 Server
  •  
  • Sun Netra 440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-V4x0
  •  




In this Document
Purpose
Details
References


Applies to:

Sun Fire V440 Server - Version All Versions and later
Sun Fire V445 Server - Version All Versions and later
Sun Netra 440 Server - Version All Versions and later
Oracle Solaris on SPARC (64-bit)

Purpose



To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - SPARC Legacy Servers



 A quick reference to see how the CPU's and dimms are layed out in the V440, Netra 440 & V445

Details

Mother Board SlotCPU#P# (Always 0)Bank# Dimm#Dimm "J" #
J0301 0 0 B0 D0 J0601
B0 D1 J0602
B1 D0 J0701
B1 D1 J0702
J0401 1 0 B0 D0 J0601
B0 D1 J0602
B1 D0 J0701
B1 D1 J0702
J0501 2 0 B0 D0 J0601
B0 D1 J0602
B1 D0 J0701
B1 D1 J0702
J0601 3 0 B0 D0 J0601
B0 D1 J0602
B1 D0 J0701
B1 D1 J0702

 

To assist in determining DIMM size see: