Solution Type Predictive Self-Healing Sure Solution 1480040.1 : ZFS-8000-QJ - Missing data on a ZFS device. Applications are unaffected if sufficient replicas exist.
In this Document
Applies to:Oracle SuperCluster M8 HardwareOracle SuperCluster M7 Hardware SPARC M7-8 SPARC M7-16 SPARC T7-4 Information in this document applies to any platform. PurposeThis document provides additional information for message ID: ZFS-8000-QJ Scope
DetailsType: Fault
fault.fs.zfs.vdev.dtl Severity: Minor Description Missing data on a ZFS device in a pool. Applications are unaffected if sufficient replicas exist. Automated Response An attempt will be made automatically to recover the data. The device and pool will be degraded. Impact The device and pool may continue functioning in degraded state until data is recovered. Suggested Action for System Administrator For ZFS Storage Appliances proceed directly to the PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1) Otherwise use 'fmadm faulty' to provide a more detailed view of this event. Run 'zpool status -lx' for more information. User can wait for system to start resilver automatically or "zpool scrub" could be done to recover the data. Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required. Attachments This solution has no attachment |
||||||||||||||||||
|