Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1454231.1
Update Date:2017-05-23
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1454231.1 :   Niwot SAS cable pinout differs from system board SAS cable  


Related Items
  • Netra SPARC T4-1 Server
  •  
  • SPARC T4-1
  •  
  • SPARC T3-1
  •  
  • Sun Hardware - Generic
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T3
  •  




Applies to:

SPARC T3-1
Netra SPARC T4-1 Server
SPARC T4-1
Sun Hardware - Generic
Information in this document applies to any platform.

Purpose

Niwot SAS cable differs from system board SAS cable 

Details

When adding a Sun Storage 6Gb SAS PCIe RAID HBA Internal Card (Niwot) to a system, please note that its SAS cable pinout differs from the SAS cable that connects to a system board.  The Niwot SAS cable must be used when connecting it to the disk backplane.  Also, if a Niwot is removed, the SAS cable listed in the Sun System handbook must be used to connect the system board to the disk backplane.

 

Cable Info:

Netra T4-1 cable assembly: ( NIWOT HBA )( single cable required )
X8224A-N 1     SAS Cable Kit   530-4088 [C]     4× Mini SAS Cable, 90° SFF-8087 to 90° SFF-8087


SPARC T4-1 cable assembly: ( NIWOT HBA )( may require 2 cables depending on configuration )
If SAS cabling for X-Option SGX-SAS6-R-INT-Z is needed, order X-Option SE3X4A11Z SAS Cable Kit.
SE3X4A11Z 4     594-6778     SAS Cable Kit     530-3891    4x Mini SAS Cable, SFF-8087 to SFF-8087, 450mm

 

Note: Steve Trullo & Alex Robanivich are the engineers related to the NIWOT.