Solution Type
Predictive Self-Healing Sure
Solution
1433411.1
:
ZFS-8000-PE - ZFS device has insufficient replicas to continue
Related Items |
- SPARC T8-1
- SPARC T8-4
- SPARC T7-4
- SPARC M7-8
- SPARC M8-8
- Oracle SuperCluster M7 Hardware
- SPARC T8-2
- SPARC T7-2
- Oracle SuperCluster M8 Hardware
- SPARC T7-1
- SPARC M7-16
- Solaris Operating System
- Solaris Operating System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
Applies to:
Solaris Operating System - Version 8 6/00 U1 and later
SPARC T7-1
SPARC T7-2
SPARC T7-4
SPARC T8-1
All Platforms
Purpose
Provide additional information for message ID: ZFS-8000-PE
Details
Type
- Fault
- fault.fs.zfs.no_replicas
Severity
- Major
Description
- ZFS device has insufficient replicas to continue.
Automated Response
- No automated response will occur.
- ZFS Storage Appliances will reboot.
Impact
- The pool is no longer accessible.
Suggested Action for System Administrator
-
A device within a ZFS pool has insufficient replicas to continue.
Check that all SAS cables are attached.
Check that all members of the zpool are seen by the OS and reattach if necessary.
If the above procedures do not address the issue it is highly recommended that the customer cease troubleshooting and contact Oracle Support.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)