SPX86-8003-73 - Lack of AC input power.
Related Items |
- Sun Server X3-2L
- Sun Server X3-2
- Exalogic Elastic Cloud X3-2 Hardware
- Oracle Database Appliance X4-2
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Sun Microsystems > Servers > x64 Servers
Exalogic Elastic Cloud X3-2 Hardware
Sun Server X3-2
Sun Server X3-2L
Oracle Database Appliance X4-2
Information in this document applies to any platform.
Purpose
This document provides additional information for message ID: SPX86-8003-73
Scope
Details
Lack of AC input power.
Type
- Fault
- fault.chassis.power.ext-fail
Severity
- Minor
Description
Message ID: SPX86-8003-73 indicates that the ILOM fault manager has received
an error report indicating a loss of AC input to a power supply has occurred.
The power supply is not at fault.
Automated Response
The chassis-wide power supply fault LED will be illuminated.
Service Processor will display status of the PSU LED indicator as: /SYS/PS_FAULT = On
The chassis-wide service required LED on the server will be illuminated.
Service Processor will display status of the chassis-wide LED indicator as: /SYS/SERVICE = On
Impact
- The server continues to operate as long as there is a redundant power supply.
Suggested Action for System Administrator
Please verify that external AC input to the power supply is present.