Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1429954.1
Update Date:2018-01-09
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1429954.1 :   SPX86-8003-73 - Lack of AC input power.  


Related Items
  • Sun Server X3-2L
  •  
  • Sun Server X3-2
  •  
  • Exalogic Elastic Cloud X3-2 Hardware
  •  
  • Oracle Database Appliance X4-2
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Scope
Details
References


Applies to:

Sun Microsystems > Servers > x64 Servers
Exalogic Elastic Cloud X3-2 Hardware
Sun Server X3-2
Sun Server X3-2L
Oracle Database Appliance X4-2
Information in this document applies to any platform.

Purpose

This document provides additional information for message ID: SPX86-8003-73

Scope

 

Details

Lack of AC input power.

 

Type

Fault
   fault.chassis.power.ext-fail

Severity

Minor

Description

Message ID: SPX86-8003-73 indicates that the ILOM fault manager has received
an error report indicating a loss of AC input to a power supply has occurred.

The power supply is not at fault.

Automated Response

The chassis-wide power supply fault LED will be illuminated.
Service Processor will display status of the PSU LED indicator as: /SYS/PS_FAULT = On

The chassis-wide service required LED on the server will be illuminated.
Service Processor will display status of the chassis-wide LED indicator as: /SYS/SERVICE = On

Impact

The server continues to operate as long as there is a redundant power supply.

Suggested Action for System Administrator

Please verify that external AC input to the power supply is present.

Refer to the following document for the latest procedures for displaying event content in preparation
for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)

 